NUGROHO, MUHAMMAD FARID and suwarno, suwarno (2019) PENYETELAN RELE DIFERENSIAL PADA TRANSFORMATOR TENAGA I 60 MVA DI GARDU INDUK ANGKE 150/20 KV. Diploma thesis, ITPLN.
Muhammad Farid Nugroho (2016-71-150).pdf
Restricted to Registered users only
Download (10MB)
Abstract
Rele diferensial sendiri merupakan proteksi utama pada transfomator tenaga yang bekerja tanpa koordinasi dengan rele lain adalah sifat dari rele diferensial itu sendiri yaitu sangat selektif dan cepat dalam mengatasi gangguan. Rele diferensial ini mempunyai daerah pengaman yang dibatasi oleh pemasangan transformator arus (CT). Rele diferensial disini untuk mengetahui performa rele tersebut sehingga dilakukan penyetelan rele diferensial berupa perhitungan secara teori dengan melakukan pengambilan data di Gardu Induk Angke slope1 30% dan slope2 100%. Kemudian dilakukan perhitungan teori dengan memperhatikan nilai error mismatch 0,225%, kesalahan CT 10%, faktor keamanan 5%, arus eksitasi 1%, dan akurasi rele 11,76%, maka didapatkan slope1 sebesar 30% dan slope2 sebesar 60% dengan memperhatikan beberapa aspek sehingga diketahui persentase slope tersebut dan didapatkan arus setelan sebesar 1,5 A. Perbandingan setting dari Gardu Induk Angke dengan perhitungan tidak terlalu berbeda jauh dan simulasi pengujian dilakukan dengan menggunakan software 87T by sumandari menggunakan data pengujian dan data slope perhitungan dan setting lapangan didapatkan trip pada pengujian 4 pada fasa R,S dan tidak trip pada fasa T disebabkan arus gangguan kurang dari arus setting sehingga tidak membuat rele bekerja. Hal ini membuktikan rele diferensial bekerja dengan zona pengamanan dan mengurangi trip di zona eksternal.
Differential relay transfomer protection itself is the main power that does work without coordination with other rele is the nature of differential relay itself that is very selective and fast in overcoming disorder. It has this differential relay safety area bounded by the installation of a current transformer (CT). Differential relay here to find out the performances of the relay so done tuned differential relay of reckoning in theory by taking data in the substation angke slope1 30% and slope2 100%.Then performed the calculations theory with regard to the value error mismatch 0,225%, percent the CT 10%, security factor 5%, the excitation current 1%, and accuracy of the relay 11,76%, obtained slope 1 as much as 30% and slope2 as much as 60% with regard to some aspects so that the slope known percent and recovered the current suit 1,5 A. The setting of main station angke by calculation not too similar testing done as using software 87t by sumandari used data on testing and data and setting the field slope or trip on testing 4 in phase on R , S and not trip on the phase T due to a fault current less of a current setting so that does not make relay work .This proved differential relay work to that zone of security and reduce trip in the external.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Rele, Rele Diferensial, Transformator, Setting, Arus Gangguan. Relay, Differential Relay, Transformer, Setting, Fault Current. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 12 Feb 2026 08:30 |
| Last Modified: | 12 Feb 2026 08:30 |
| URI: | https://repository.itpln.ac.id/id/eprint/5013 |