Abstract

Transformator merupakan peralatan listrik yang dibutuhkan dalam proses penyaluran energi listrik dari pembangkit menuju ke pusat beban. Transformator dapat mengkonversi tegangan menjadi lebih besar atau lebih kecil untuk menyesuaikan kebutuhan. Dalam mengkonversi tegangan listrik, selalu ada energi yang berubah menjadi panas (heat loss) pada inti dan belitan transformator. Rugi inti tidak dipengaruhi oleh besarnya arus pembebanan transformator, sedangkan rugi belitan bisa berubah-ubah akibat arus pembebanan. Rugi-rugi transformator distribusi mengakibatkan kerugian teknis yang ditanggung oleh PLN, untuk mengetahui besar kerugian yang ditanggung PLN selama pemakaian transformator distribusi maka dilakukan perhitungan rugi-rugi dengan metode perkiraan pertumbuhan beban dimasa yang akan datang. Penelitian dilakukan pada trafo distribusi di gardu beton CKG181 yang beralamat di jalan Pedongkelan Belakang, RT/RW 08/016 Kapuk, Cengkareng. Dari perkiraan pertumbuhan beban, diperoleh hasil bahwa transformator dapat dioprasikan selama 14 tahun dengan biaya rugi total akibat adanya daya yang hilang sebesar Rp. 565.146.992,4.

The transformer is a piece of electrical equipment needed in the process of distribute electrical energy from the generator to the load center. The transformer can convert the voltage to be larger or smaller to adjust the needs. In converting electric voltage, there is always an energy that turns into heat (heat loss) in the core and transformer winding. The core loss is not affected by the amount of the transformer loading current, while the winding losses can change due to the loading current. Losses of distribution transformers result in technical losses borne by PLN, to find out the extent of losses borne by PLN during the use of distribution transformers, the losses are calculated using the estimated method of load growth in the future. The study was conducted on a distribution transformer at the CKG181 concrete substation located at Pedongkelan Belakang street, RT / RW 08/016 Kapuk, Cengkareng. From the estimated load growth, the results show that the transformer can be operated for 14 years with a total loss due to the power loss of Rp. 565.146.992,4.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Rugi-rugi daya, transformator distribusi, pertumbuhan beban Power losses, distribution transformer, load growth
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 12 Feb 2026 08:37
Last Modified: 12 Feb 2026 08:37
URI: https://repository.itpln.ac.id/id/eprint/5014

Actions (login required)

View Item
View Item