KUTY, MUHAMMAD ARAFAT AR and Sari, Dewi Purnama (2019) PERBAIKAN JATUH TEGANGAN DAN RUGI DAYA PADA SAMBUNGAN RUMAH MULTI PELANGGAN DI GARDU DISTRIBUSI MD 9 DI MARUNDA JAKARTA UTARA. Diploma thesis, ITPLN.
MUHAMMAD ARAFAT AR KUTY (2016-71-154).pdf
Restricted to Registered users only
Download (4MB)
Abstract
Jaringan sistem distribusi di Kampung Turi Jaya Desa Segeramakmur termasuk wilayah kerja PT. PLN (Persero) UP3 Marunda. Pada wilayah ini jumlah titik sambungan yang dihasilkan melebihi standar yakni didapatkan sebanyak 19 tarikan, dimana berdasarkan PUIL 2010 menyatakan bahwa dalam satu Sambungan Layanan Pelanggan (SLP) dapat disambung maksimum 5 pelanggan. Jika pemasangan sambungan rumah (SR) tidak sesuai dengan standar konstruksi jaringan distribusi PLN maka hal tersebut menyebabkan timbulnya rugi daya pada PLN dan jatuh tegangan pada pelanggan. Berdasarkan hasil pengukuran dan perhitungan yang telah dilakukan dengan membandingkan 5 pelanggan yaitu kode rumah 12, kode rumah 19, kode rumah 50, kode rumah 86, dan kode rumah 103 , maka didapatkan rugi daya sebesar 517,23 watt, 1280,38 watt, 332,59 watt, 457,07 watt, 221,93 watt dan jatuh tegangan sebesar 15,98%, 21,19%, 19,35%, 18,85%, 14,28%. Setelah melihat data yang ada hal ini membuktikan bahwa pemasangan sambungan rumah (SR) yang tidak standar menyebabkan jatuh tegangan dan rugi daya. Untuk mengatasi hal tersebut maka harus dilakukan perluasan jaringan, sehingga diperoleh penurunan rugi daya sebesar 0,80 watt, 8,90 watt, 15,31 watt, 1,19 watt, dan 39,48 watt dan penurunan jatuh tegangan sebesar 0,045%, 0,045%, 0,09%, 0,045%, 0,136%.
Network distribution system in Kampung Desa Jaya Turi Segeramakmur including working area of PT. PLN (Persero) UP3 Marunda. In this region the number of connection points generated exceeds the standards gained as much as 19 tug, which is based PUIL 2010 states that in the Customer Service Line (CSL) can be connected up to 5 customers. If residential connections (RC) does not comply with construction standards PLN distribution network then it can cause power losses in the PLN and the voltage drop on the customer. Based on the results of measurements and calculations have been carried out by comparing the 5 customers are house code 12, code 19 houses, house code 50, code 86 houses, and the house code 103, then obtained the power losses amounted to 517.23 watts, watt 1280.38, 332 , 59 watts, watt 457.07, 221.93 watts and a voltage drop of 15.98%, 21.19%, 19.35%, 18.85%, 14.28%. After looking at the data this proves that residential connections (RC) are not standardized cause a voltage drop and power loss. To solve it is to do the expansion of the network, in order to obtain a decrease power loss of 0.80 watts, 8.90 watts, 15.31 watts, 1.19 watts and 39.48 watts and decrease the voltage drop amounting to 0.045%, 0.045%, 0.09%, 0.045%, 0.136%.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Jatuh tegangan, rugi daya, sambungan rumah. The voltage drop, power losses, the home connection. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 12 Feb 2026 08:46 |
| Last Modified: | 12 Feb 2026 08:46 |
| URI: | https://repository.itpln.ac.id/id/eprint/5015 |