KRISMANTANA, ALDIE RYAN and Pasra, Nurmiati (2019) PENGGUNAAN SISTEM PROTEKSI OVER CURRENT RELAY PADA MOTOR PRIMARY AIR FAN 3A DI PLTU PELABUHAN RATU. Diploma thesis, ITPLN.
PROYEK AKHIR ALDIE.pdf
Restricted to Registered users only
Download (20MB)
Abstract
Motor primary air fan 3A merupakan salah satu mesin yang sangat penting di dalam suatu pembangkit listrik dikarenakan perannya begitu krusial dalam proses terjadinya pembakaran di dalam furnace untuk dapat menghasilkan uap. Sehingga perlu adanya proteksi yang terpasang guna mencegah terjadinya gangguan. Gangguan pada motor primary air fan 3A dapat disebabkan adanya arus gangguan hubung singkat. Gangguan tersebut apabila terjadi pada motor tentu akan mengakibatkan motor mengalami kerusakan sehingga berdampak pada penurunan beban (derating) pada pembangkit. Adapun hasil nilai arus hubung singkat tiga fasa yang akan terjadi ditentukan pada tiga kondisi yang berbeda. kondisi pertama = 9486,09 A, kondisi kedua = 5573,96 A dan kondisi ketiga = 8155,64 A. Proteksi pada motor sangat menentukan keandalan pada pengoperasian sistem pembangkit sehingga perlu adanya penyetelan proteksi yang dapat mengamankan dari gangguan tersebut agar dapat memutus dan menghindari kerusakan yang terjadi pada motor. Pada pencegahan dari gangguan arus hubung singkat diperlukan proteksi over current relay instantaneous high level dan low level. Adapun setting yang terpasang untuk mengamankan motor pada nilai, high level = 8,02 A dan low level = 4,00 A
The 3A motor primary fan is one of the most important engines in a power plant because of its role in the process of increasing combustion in a furnace to produce steam. Needs to be removed. Interference with the primary fan motor 3A can cause a short circuit fault current. The disturbance occurs on the motor, of course, will experience damage when decreased. While the results of the three phase short circuit current that will occur are determined under three different conditions. The first condition = 9486.09 A, the second condition = 5573.96 A and the third condition = 8155.64 A. Protection of the motor is very crucial in the discussion of the funding system so that the necessary protection settings are needed Damage to the motor. In the event of a short-circuit current problem protection is needed for high-current and low-level current relays. While the settings are set for the motor at value, high level = 8.02 A and low level = 4.00 A.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Primary air fan motor 3A, over current relay, high level, low level. Motor primary air fan 3A, over current relay, high level, low level. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 12 Feb 2026 09:13 |
| Last Modified: | 12 Feb 2026 09:13 |
| URI: | https://repository.itpln.ac.id/id/eprint/5020 |