PERHITUNGAN KAPASITAS AUXILIARY TRANSFORMER UNIT PADA SISTEM PEMAKAIAN SENDIRI DI PT. INDONESIA POWER UJP BANTEN 1 SURALAYA

WICAKSONO, BAHTIAR BIMO and Erlina, Erlina (2019) PERHITUNGAN KAPASITAS AUXILIARY TRANSFORMER UNIT PADA SISTEM PEMAKAIAN SENDIRI DI PT. INDONESIA POWER UJP BANTEN 1 SURALAYA. Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR BAHTIAR BIMO WICAKSONO 2016 71 164 D3 ELEKTRO.pdf] Text
PROYEK AKHIR BAHTIAR BIMO WICAKSONO 2016 71 164 D3 ELEKTRO.pdf
Restricted to Registered users only

Download (3MB)

Abstract

Instalasi pemakaian sendiri merupakan hal yang sangat penting bagi proses pembangkitan energi listrik. Pada PLTU, instalasi pemakaian sendiri sangat berpengaruh pada kinerja peralatan tersebut. Karena semua peralatan tersambung pada instalasi pemakaian sendiri. Ada beberapa transformator pemakaian sendiri di UJP Banten 1 Suralaya diantaranya adalah Unit Auxiliary Transformator (UAT) dan Unit Station Transformator (UST), Besar nilai pembebanan pada Unit Transformator Auxiliary pada saat kondisi normal running sebesar 26,7 MVA dari 34 MVA dimana persentase pembebanan sebesar 78,7 % yang berarti masih dalam keadaan optimal dan sesuai dengan standar yang berlaku. Kemudian ketika saat kondisi pembebanan penuh, nilai pembebanan mencapai 33,5 MVA dari 34 MVA dimana dimana persentase pembebanan sebesar 98,4 %. Pada 4 Trafo UST didapat Pada Water System Transformer dibebani sebesar 1167,6 kVA dari 1600 kVA dengan persentase sebesar 72,9 %. Pada Turbine Transformer dIbebani 865,6 kVA dari 1600 kVA dengan persentase 54,1 %. Pada ESP Transformer dibebani sebesar 621,1 kVA dari 1600 kVA dengan persentase sebesar 38,8 %. Pada Boiler Transformer dibebani sebesar 487,7 kVA dari 2500 kVA dengan persentase sebesar 19,5 %.

The installation itself is very important for the process of generating electricity. At the power plant, the use of the installation itself is very influential on the performance of the equipment. Because all equipment is connected to the use of self-installation. There are a number of self-use transformers at UJP Banten 1 Suralaya including the Auxiliary Transformer Unit (UAT) and Station Station Transformer Unit (UST). 78.7% which means that it is still in an optimal state and in accordance with applicable standards. Then when the condition is full, the loading value reaches 33.5 MVA from 34 MVA where the percentage of loading is 98.4%. In 4 UST transformers obtained in the Transformer Water System burdened 1167.6 kVA from 1600 kVA with a percentage of 72.9%. The Turbine Transformer is loaded with 865.6 kVA out of 1600 kVA with a percentage of 54.1%. At ESP Transformer, the load is 621.1 kVA from 1600 kVA with a percentage of 38.8%. The Transformer Boiler is loaded with 487.7 kVA out of 2500 kVA with a percentage of 19.5%.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Self Usage Installation, Transformer Capacity, Auxiliary Transformer Unit Instalasi Pemakaian Sendiri, Kapasitas Trafo, Unit Auxiliary Transformator.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 12 Feb 2026 09:18
Last Modified: 12 Feb 2026 09:18
URI: https://repository.itpln.ac.id/id/eprint/5021

Actions (login required)

View Item
View Item