PENGATURAN EKSITASI PADA TEGANGAN KELUARAN GENERATOR UNIT 1-4 PLTU SURALAYA

NAWAWI, FAHRUL DZAKIRIN and oktaviana, tri wahyu (2019) PENGATURAN EKSITASI PADA TEGANGAN KELUARAN GENERATOR UNIT 1-4 PLTU SURALAYA. Diploma thesis, ITPLN.

[thumbnail of COVER_PA[1].pdf] Text
COVER_PA[1].pdf

Download (235kB)
[thumbnail of lembar pengesahan.pdf] Text
lembar pengesahan.pdf

Download (200kB)
[thumbnail of abstrak_inggris[1].pdf] Text
abstrak_inggris[1].pdf

Download (246kB)
[thumbnail of abstrak[2].pdf] Text
abstrak[2].pdf

Download (243kB)
[thumbnail of BAB I d3k.pdf] Text
BAB I d3k.pdf

Download (161kB)
[thumbnail of BAB_2_Teori_Dasar.pdf] Text
BAB_2_Teori_Dasar.pdf

Download (1MB)
[thumbnail of BAB_III_d3k.pdf] Text
BAB_III_d3k.pdf
Restricted to Registered users only

Download (512kB)
[thumbnail of BAB_4.pdf] Text
BAB_4.pdf
Restricted to Registered users only

Download (571kB)
[thumbnail of BAB_V.pdf] Text
BAB_V.pdf
Restricted to Registered users only

Download (242kB)
[thumbnail of DAFTAR_PUSTAKA[1].pdf] Text
DAFTAR_PUSTAKA[1].pdf

Download (146kB)

Abstract

Kebutuhan energi merupakan hal yang penting dalam kehidupan manusia untuk meningkatkan kesejahteraan hidup. Salah satu kebutuhan energi tersebut dalam kebutuhan manusia pada masa sekarang adalah energi listrik. Pada PLTU suralaya unit 1-4, generator merubah energi gerak dari uap menjadi energi listrik yang digunakan untuk memenuhi kebutuhan listrik, PLTU suralaya menghasilkan tegangan keluaran sebesar 23 KV. Sistem eksitasi adalah pemberian arus listrik searah untuk membuat kutub magnet pada rotor generator. Dengan mengatur arus eksitasi maka dapat mengatur daya reaktif dan tegangan keluaran generator yang ditentukan dari jaringan yang terhubung secara paralel dengan generator. Jika beban di jaringan rendah maka tegangan keluaran generator naik melebihi tegangan refrensi sebaliknya jika beban di jaringan tinggi maka tegangan keluaran generator turun dibawah tegangan refrensi. Jika tegangan keluaran generator naik melebihi tegangan refrensi maka pada sistem eksitasi akan mengurangi suplai arus eksitasi pada rotor generator sehingga pada rotor generator mengalami penurunan fluks magnet menyebabkan daya reaktif dan tegangan keluaran generator turun, begitupun sebaliknya. Dalam penelitian ini mahasiswa menggunakan metode kualitatif yaitu mengamati perubahan arus eksitasi terhadap tegangan keluaran generator dan daya reaktif. Mahasiswa melakukan observasi lapangan pada tanggal 4 Februari – 31 Mei 2019, melakukan wawancara terhadap teknisi listrik mengenai sistem eksitasi dan mahasiswa melakukan pengambilan data pada tanggal 10 Maret 2019. Hasil dari pengamatan ini tegangan keluaran generator berada dikisaran 23 KV menandakan keandalan sistem tinggi.

Energy requirement is very important for people to increase prosperity. One of energy requirement for people now is electric energy. In PLTU Suralaya unit 1-4, generator convert motion energy from steam to electrical energy that is used by people to fulfill electric energy requirement, PLTU Suralaya produce the generator voltage out as uch as 23 KV. Excitation system is giving direct current to make magnetic field in rotor of generator. By controlling excitation current power plant can control reactive power and the generator voltage out that is determined by infinite bus that connected parallelly with generator. If the load in infinte bus is low so the generator voltage out is up above the reference voltage the opposite if the load in infinite bus is high so the generator voltage out is down under the reference voltage. If the generator voltage out rises up to exceed the reference voltage so in excitation system will reduces excitation current supply to rotor of generator, it will reduce flux magnetic in rotor of generator. This condition made reactive power and the generator voltage out is down and oppositely. In this final project colleger uses qualitative methode that observes about changing of excitation current with the generator voltage out and reactive power. Colleger got an conversation in PLTU Suralaya unit 1-4 in 4 February – 31 May 2019, getting conversation with electrical engineer and taking data in 10 March 2019. The result from this observation is the generator voltage out in the range of 23 KV, it’s proving that the system maintained its stability.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: load , the generator voltage out, excitation current beban, tegangan keluaran, arus eksitasi