STUDI PROTEKSI OCR DAN GFR MOTOR LISTRIK PENGGERAK FORCED DRAFT FAN (FD FAN) 6 KV DI PLTU BANTEN 3 LONTAR UNIT 3

OTNIEL, HARKESNAL and Putri, Tri Wahyu Oktaviana (2019) STUDI PROTEKSI OCR DAN GFR MOTOR LISTRIK PENGGERAK FORCED DRAFT FAN (FD FAN) 6 KV DI PLTU BANTEN 3 LONTAR UNIT 3. Diploma thesis, ITPLN.

[thumbnail of COVER PROYEK AKHIR SEKOLAH TINGGI TEKNIK PLN.pdf] Text
COVER PROYEK AKHIR SEKOLAH TINGGI TEKNIK PLN.pdf

Download (12kB)
[thumbnail of PROYEK AKHIR HARKESNAL OTNIEL (2016 71 171).pdf] Text
PROYEK AKHIR HARKESNAL OTNIEL (2016 71 171).pdf
Restricted to Registered users only

Download (2MB)

Abstract

Motor asinkron (motor induksi) banyak digunakan pada pembangkit sistem tenaga listrik seperti contohnya pada Forced Draft Fan (FDF) .Dalam sistem tenaga listrik, supaya dapat beroperasi dengan andal, maka diperlukan sistem proteksi. Sistem proteksi berperan penting dalam mendeteksi adanya gangguan dan untuk mencegah kerusakan yang diakibatkan gangguan. Sistem proteksi yang baik akan mengisolasi daerah gangguan dan mencegah terjadinya padam pada sistem lain yang tak terganggu. Sistem proteksi yang utama dalam motor listrik yaitu Over current relay(OCR) dan Ground fault relay(GFR). Hal ini akan meningkatkan keandalan sistem yaitu menjaga kontinyuitas suplai beban. Proyek akhir ini bertujuan untuk menyampaikan studi proteksi motor listrik besar dengan studi kasus Forced Draft Fan (FDF) di Unit Jasa Pembangkit PLTU Banten 3 Lontar. Dari hasil studi pada proyek akhir ini di dapatkan perhitungan settingan arus dan waktu yang mencakup Overcurrent protection dan Ground fault protection. Sistem pembangkit listrik tenaga uap pada motor listrik Forced draft fan. Untuk itu dilakukan penyetelan ulang perencanaan relay arus lebih dan arus satu fasa ke tanah. Pengumpulan data kelistrikan yang diperlukan. Kemudian menetukan titik letak relay arus lebih, menghitung impedansi dan arus hubung singkat.Setelah semua didapatkan maka digunakan untuk menghitung nilai arus settingan dan nilai waktu kerja pada relay. Hasil perhitungan nilai settingan relay di motor Forced draft fan 6 KV adalah untuk OCR(Instantaneous) nilai setingan arus primernya adalah 567 A dan untuk arus sekunder adalah 9,45 A. OCR(Invers time limit) nilai setingan arus primernya adalah 108 A dan untuk arus sekunder adalah 1,8 A Nilai settingan waktu kerja nya adalah 12 detik dengan nilai TMS-nya 0,845 detik. OCR(Definite) nilai setingan arus primernya adalah 81 A dan untuk arus sekunder adalah 1,35 A.Untuk GFR nilai setingan arus primernya adalah 5,4 A dan untuk arus sekunder adalah 0,08 A. Nilai settingan waktu kerja nya adalah 0,4 detik dengan nilai TMS-nya 0,2 detik.

Asynchronous motors (induction motors) are widely used in power systems such as the Forced Draft Fan (FDF). In an electric power system, in order to operate reliably, a protection system is needed. The protection system plays an important role in detecting interference and to prevent damage caused by interference. A good protection system will isolate the area of interference and prevent outages in other systems that are not interrupted. The main protection systems in electric motors are Over current relay (OCR) and Ground fault relay (GFR). This will increase the reliability of the system by maintaining the continuity of the supply load. This final project aims to deliver a large electric motor protection study with a case study of the Forced Draft Fan (FDF) at the Banten 3 Lontar Power Plant Generation Services Unit. From the results of studies in this final project, we get the calculation of current and time settings which include Overcurrent protection and Ground fault protection. Steam power generation system on electric motor Forced draft fan. For this reason, it is necessary to reset the overcurrent and single phase current to ground relay planning. Electrical data collection required. Then determine the location of the overcurrent relay, calculate the impedance and short circuit current. After all is obtained, it is used to calculate the value of the setting current and the value of the working time of the relay. The results of the calculation of the value of the relay settings in the motor Forced draft fan 6 KV are for OCR (Instantaneous) the value of the primary current setting is 567 A and for the secondary current is 9.45 A. OCR (inverse time limit) the value of the primary current setting is 108 A and for the secondary current is 1.8 A The value of the working time setting is 12 seconds with a TMS value of 0.845 seconds. OCR (Definite) value of the primary current setting is 81 A and for the secondary current is 1.35 A. For GFR the primary current value is 5.4 A and for the secondary current is 0.08 A. The value of the working time setting is 0, 4 seconds with a TMS value of 0.2 seconds.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Protection, FD Fan, Power Plant, Asynchronous Motor, Management Relay Proteksi, FDF, PLTU, Motor Asinkron (Motor Induksi), Relai Manajemen
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 12 Feb 2026 12:33
Last Modified: 12 Feb 2026 12:33
URI: https://repository.itpln.ac.id/id/eprint/5028