ASSESMENT SALURAN KABEL TEGANGAN MENENGAH 20 KV DENGAN OSCILLATING WAVE TEST SYSTEM DALAM RANGKA PEMELIHARAAN PADA PENYULANG RAMPING DI PT. PLN (PERSERO) UP3 MENTENG

DARMAWAN, HAVIZ and Kurniasih, Novi (2019) ASSESMENT SALURAN KABEL TEGANGAN MENENGAH 20 KV DENGAN OSCILLATING WAVE TEST SYSTEM DALAM RANGKA PEMELIHARAAN PADA PENYULANG RAMPING DI PT. PLN (PERSERO) UP3 MENTENG. Diploma thesis, ITPLN.

[thumbnail of HAVIZ DARMAWAN (2016-71-172).pdf] Text
HAVIZ DARMAWAN (2016-71-172).pdf
Restricted to Registered users only

Download (3MB)

Abstract

Dalam penyaluran sistem distribusi tenaga listrik khususnya saluran kabel tegangan menengah (SKTM) dibutuhkan pemeliharaan guna menjaga keandalan sistem distribusi tetap terjaga secara kontinuitas. Penelitian ini membahas tentang pengaruh partial discharge SKTM 20 kV di segmen gardu KN 4 ke T 274 pada penyulang Ramping. Pada penelitian tersebut dilakukan assesment kabel yang memiliki cacat rongga atau void sehingga dapat menimbulkan peristiwa partial discharge. Assessment kabel menggunakan alat Oscillating Wave Test System (OWTS) yang mana dalam pengujiannya menghasilkan pemetaan PD, hasil pengukuran partial discharge, serta panjang kabel dan banyaknya jumlah jointing. Dari hasil pengukuran partial discharge pada saat kondisi sebelum adanya perbaikan kabel diperoleh nilai partial discharge di fasa R (L1) sebesar 5699 pC, fasa S (L2) 11803 pC,fasa (L3) 7476 pC, sedangkan setelah adanya perbaikan nilai partial discharge di fasa L1 sebesar 176 pC, L2 233 pC, L3 169 pC. Dari hasil perhitungan tegangan partial discharge sebelum adanya perbaikan kabel diperoleh pada fasa R (L1) sebesar 0,016 V, fasa S (L2) 0,033 V, fasa T (L3) 0,021 V, sedangkan setelah adanya perbaikan kabel nilai tegangan di fasa R (L1) sebesar 0,0005 V, fasa S (L2) 0,0006 V, fasa T (L3) 0,00048 V. Setelah dilakukan adanya perbaikan kabel maka dapat disimpulkan adanya peningkatan dari kondisi kabel atau health index yang awalnya mempunyai nilai poin 6 dengan status sangat buruk menjadi poin 4 dengan status waspada yang dilihat dari penjumlahan multipier frekuensi. Dengan kondisi kabel yang meningkat dapat menjaga keandalan penyaluran sistem distribusi tenaga listrik khususnya pada saluran kabel tegangan menengah 20 kV dengan memperhatikan rekomendasi pemeliharan yang sudah terjadwal.

In the distribution of electrical power distribution systems in particular medium-voltage cable lines (SKTM) required maintenance in order to maintain the reliability of the distribution system is maintained in continuity. This study discusses the effects of partial discharge SKTM 20 kV in the substation segment KN 4 to T 274 on Ramping feeder. In the study conducted assessment defective cable that has a cavity or void that can cause partial discharge events. Assessment cable using the tool Oscillating Wave Test System (OWTS) which in the yield mapping PD testing, partial discharge measurement results, as well as the cable length and the number of jointing. From the results of partial discharge measurement at the time of the condition before the repair cable partial discharge values obtained in phase R (L1) of 5699 pC, phase S (L2) 11803 pC, phase (L3) 7476 pC, where as after repair value of partial discharge in phase R (L1) of 176 pC, phase S (L2) 233 pC, phase T (L3) 169 pC, after do the repair wiring it can be concluded the increase of cable or health condition index that initially has a value of 6 points with a very bad status into points 4 with the alert status as seen from multiplayer sum frequency. With increasing cable conditions can maintain the reliability of the distribution of electrical power distribution systems, especially on cable lines 20 kV medium voltage considering recommendations that have been scheduled maintenance.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: medium-voltage cable channel, cable assessment, partial discharge, oscillating wave test system, health index saluran kabel tegangan menengah, assesment kabel, partial discharge, oscillating wave test system, health index
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 12 Feb 2026 12:56
Last Modified: 12 Feb 2026 12:56
URI: https://repository.itpln.ac.id/id/eprint/5029