PENGARUH SISTEM EKSITASI TERHADAP TEGANGAN KELUARAN GENERATOR PADA UNIT 2 PLTU BANTEN 3 LONTAR

HS, PERINAL HADI HABIBI and Erlina, Erlina (2019) PENGARUH SISTEM EKSITASI TERHADAP TEGANGAN KELUARAN GENERATOR PADA UNIT 2 PLTU BANTEN 3 LONTAR. Diploma thesis, ITPLN.

[thumbnail of TA Perinal Hadi Habibi Hs.pdf] Text
TA Perinal Hadi Habibi Hs.pdf
Restricted to Registered users only

Download (10MB)

Abstract

Unit Jasa Pembangkitan (UJP) Banten 3 Lontar merupakan bagian perusahaan pembangkitan tenaga listrik PT. Indonesia Power yang memanfaatkan bahan bakar batu bara sebagai energi primernya. UJP Banten 3 Lontar terdiri dari 3 unit, yaitu pada setiap unitnya memiliki kapasitas daya sebesar 315 MW. Pembangkitan listrik dari menggunakan energi mekanik yang dihasilkan dari energi uap sehingga memutar turbin dengan kecepatan rotor 3000 rpm dan menghasilkan frekueansi 50 Hz serta tegangan terminal 20 kV. Seiring dengan perubahan beban dapat mempengaruhi kestabilan tegangan generator. Oleh karena diperlukan sistem eksitasi untuk menjaga kestbilan tegangan generator. Dalam pembahasan ini yaitu mengetahui pengaruh arus eksitasi terhadap tegangan keluaran generator. Dari data yag didapatkan diketahui arus eksitasi pada jam 11.00 adalah kondisi ketika arus eksitasi tinggi 1635.35A dan menghasilkan tegangan tinggi juga yaitu 20.240 V serta menghasilkan daya reaktif tinggi 98.34. Sehingga dapat dilihat bahwa peranan arus eksitasi terhadap tegangan dan daya reaktif sangat berpegaruh.

Generation Services Unit (UJP) Banten 3 Lontar is part of the power generation company PT. Indonesia Power utilizing coal fuel as primary energy. UJP Banten 3 Lontar consists of three units, namely on each unit has a power capacity of 315 MW. Electricity generation from using mechanical energy generated from the steam energy to drive turbines with a rotor speed of 3000 rpm and generates frekueansi 50 Hz and 20 kV voltage terminal. Along with the change of the load can affect the stability of the voltage generator. Therefore, excitation system is required to keep the generator voltage kestbilan. In this discussion is to know the influence of excitation current to the generator output voltage. From the data entrusted as the known excitation current at 11. 00 is a condition where high excitation current 1635.35A and produce high voltage also is 20 240 V as well as producing high reactive power of 98.34. So it can be seen that the role of the excitation current to voltage and reactive power really having an effect.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: UJP Banten 3 Lontar, Generation of Electric Energy, Excitation, Influence of Excitation UJP Banten 3 Lontar, Pembangkitan Energi Listrik, Eksitasi, Pengaruh Eksitasi
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik