PENURUNAN ARUS NETRAL DENGAN CARA PEMERATAAN BEBAN DI GARDU DISTRIBUSI GBA PT. PLN (PERSERO)

HARIANTO, DWI PUTRA REZKI and Tamam, Irvan Buchari (2018) PENURUNAN ARUS NETRAL DENGAN CARA PEMERATAAN BEBAN DI GARDU DISTRIBUSI GBA PT. PLN (PERSERO). Diploma thesis, ITPLN.

[thumbnail of COVER PA.pdf] Text
COVER PA.pdf

Download (35kB)
[thumbnail of LEMBAR PENGESAHAN.pdf] Text
LEMBAR PENGESAHAN.pdf

Download (690kB)
[thumbnail of PROYEK AKHIR 201571002.pdf] Text
PROYEK AKHIR 201571002.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Dalam sistem 3 fasa, ketidakseimbangan beban trafo sangat sering terjadi. Hal ini akibat dari beban listrik yang tidak sama karena banyaknya penambahan beban-beban listrik yang tidak memperhatikan pembebanan di tiap fasanya. Pada saat pembagian beban trafo pada fasa R, S, dan T pada umumnya diusahakan seimbang atau merata. Akan tetapi pada kenyataannya yang terjadi, pembagian bebannya tidak dapat seimbang. Apabila kurang diperhatikan dan dibiarkan begitu saja, menyebabkan beban overload disalah satu fasanya. Hal ini yang menyebabkan kabel jaringan tegangan rendah dan salah satu kumparan pada trafo terbakar akibat panas yang berlebih karena beban terlalu besar. Kinerja trafo juga tidak menjadi maksimal akibat ketidakseimbangan pembebanannya. Ketidakseimbangan beban pada trafo juga mempengaruhi juga nilai arus netralnya. Arus yang mengalir di netral trafo ini menyebabkan losses. Sehingga perlu dilakukan pemerataan beban trafo gardu distribusi secara berkala agar memperkecil ketidakseimbangan yang terjadi. Pada trafo gardu GBA dilakukan pemerataan beban untuk menurunkan arus netral yang sebelumnya sebesar 146,04 A. Kemudian turun menjadi 50,26 A setelah dilakukan pemerataan beban di gardu tersebut.

In the three-phase system, the transformer load imbalance is very common. This is a result of the electrical load is not the same because of the addition of electrical loads that do not pay attention to the loading on each phase. At the time of the distribution transformer load on phase R, S, and T are generally operated balanced or uneven. But in fact the case, the division of the burden can not be balanced. If overlooked and unpunished, causing overload load in one phase. This causes the low voltage network cable and one coil on a transformer fire due to overheat because the load is too large. Transformer performance is not a maximum due to the imbalance of the assignment. The imbalance also affects the load on the transformer neutral current value also. The current flowing in the transformer neutral is causing losses. So we need equitable distribution substation transformer load regularly in order to reduce imbalances. At the substation transformer load equalization GBA done to lower the neutral current which previously amounted to 146.04 A. Then fell to 50.26 A after the load equalization at the substation.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformers, Imbalance, Distribution, Load, Phase, Current Trafo, Ketidakseimbangan, Distribusi, Beban, Fasa, Arus
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 18 Feb 2026 06:24
Last Modified: 18 Feb 2026 07:38
URI: https://repository.itpln.ac.id/id/eprint/5080