SETYAWAN, YOHANES ANDRE DINAS and Ispranyoto, Edy (2019) MEMINIMALISIR RUGI-RUGI AKIBAT KESALAHAN PEMASANGAN TRAFO ARUS DAN TRAFO TEGANGAN DI GARDU T407 PENYULANG PROMOSI AREA MENTENG. Diploma thesis, ITPLN.
1.COVER.pdf
Download (46kB)
2.Pengesahan dllllllll.pdf
Download (144kB)
3.BAB I Pendahuluan.pdf
Download (46kB)
4.BAB II Landasan Teori2.pdf
Download (345kB)
5.BAB III Metode Penelitian 2.pdf
Restricted to Registered users only
Download (306kB)
6.BAB IV HASIL PEMBAHASAN rev.pdf
Restricted to Registered users only
Download (353kB)
7.BAB V PENUTUP.pdf
Restricted to Registered users only
Download (9kB)
8.Daftar Pustaka dan Riwayat Hidup.pdf
Restricted to Registered users only
Download (50kB)
Abstract
Rugi-rugi adalah parameter yang harus diperhatikan oleh PT. PLN (Persero), karena menunjukkan seberapa baik efisiensi suatu sistem. Semakin besar nilai rugi-ruginya, semakin kecil efisiensi sistem. Dalam sistem distribusi dapat terjadi karena beberapa faktor, salah satunya adalah kesalahan dalam pemasangan rasio trafo arus (CT) dan pemasangan rasio trafo tegangan (PT), sehingga perlu diperhatikan pada saat pemasangannya. Di PT. PLN (Persero) Disjaya Area Menteng ada pelanggan khusus dengan daya 1.730 kVA dengan rasio trafo arus (CT) dan trafo tegangan tegangan (PT) yang terpasang dengan nilai 10/200. Kerugian yang terjadi dalam kesalahan pemasangan rasio trafo arus (CT) adalah 1903,53 kWh/bulan dan kerugian karena kesalahan rasio pada trafo tegangan (PT) adalah 2852 kWh/bulan. Dengan beban 18,94 % maka batas kesalahan trafo arus (CT) sesuai dengan ketentuan yang ada adalah -0,080% dan dengan tegangan 128,7 mV maka batas kesalahan trafo tegangan (PT) sesuai dengan ketentuan yang ada adalah -1,167%.
Shrinkage is a parameter that must be considered by PT. PLN (Persero), because it shows how well the efficiency of a system is. The greater the shrinkage value, the smaller the efficiency of the system. In the distribution system can occur due to several factors, one of which is the error in the installation of the current transformer ratio (CT) and the installation of the voltage transformer ratio (PT), so it needs to be considered at the time of installation. At PT. PLN (Persero) Disjaya Menteng Area has a special customer with a power of 1,730 kVA with a current transformer (CT) ratio and a voltage voltage transformer (PT) installed with a value of 10/200. The loss that occurs in the installation error of the current transformer ratio (CT) is 1903,53 kWh / month and the loss due to error ratio on the voltage transformer (PT) is 2852 kWh / month. With a load of 18,94%, the current transformer error limit (CT) in accordance with the existing provisions is -0,080% and with a voltage of 128,7 mV, the voltage transformer error limit (PT) in accordance with the existing provisions is -1,167%.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Ratio, current transformer (CT), voltage transformer (PT), Error Rasio, trafo arus (CT), trafo tegangan (PT), Kesalahan |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 18 Feb 2026 06:56 |
| Last Modified: | 18 Feb 2026 07:40 |
| URI: | https://repository.itpln.ac.id/id/eprint/5087 |