SUSUT TEKNIS JARINGAN DISTRIBUSI TEGANGAN MENENGAH PADA PENYULANG CIPANAS DI PT. PLN (PERSERO) AREA BINTARO

GUSMANIAR, ALIFAH FARAH and Ispranyoto, Edy (2018) SUSUT TEKNIS JARINGAN DISTRIBUSI TEGANGAN MENENGAH PADA PENYULANG CIPANAS DI PT. PLN (PERSERO) AREA BINTARO. Diploma thesis, ITPLN.

[thumbnail of ALIFAH FARAH GUSMANIAR (201571007).pdf] Text
ALIFAH FARAH GUSMANIAR (201571007).pdf
Restricted to Registered users only

Download (7MB)

Abstract

Susut daya listrik merupakan persoalan klasik yang dihadapi oleh PLN dan belum dapat sepenuhnya terpecahkan. Susut merupakan kerugian energi akibat masalah teknis dan non teknis pada penyaluran energi listrik, dimana terjadi perbedaan antara pembelian kwh dan penjualan kwh. Penyebab susut teknis terjadi karena adanya resistans dan panjang kabel dari jaringan tegangan menengah yang menyebabkan drop tegangan dan adanya rugi-rugi pada transformator, sedangkan susut non teknis terjadi karena pencurian listrik dan kerusakan pada app. PLN Area Bintaro memiliki target susut sebesar 5,13%. Pada penulisan proyek akhir ini membahas tentang perhitungan susut teknis pada penyulang Cipanas. Penyulang Cipanas memiliki 12 gardu distribusi dengan panjang penyulang 14,89 kms. Pada perhitungan total susut tenis pada penyulang Cipanas didapat hasil sebesar 537,95 kWH yang terdiri dari susut pada JTM sebesar 100,44 kWH dan susut pada transformator distribusi sebesar 437,51 kWH.

Shrink power electricity is problem classic faced by PLN and not yet could fully unsolved. Shrink is loss energy effect problem technical and no technical on ed a contributionenergy electricity, where happpen difference between purchase kwh and kwh sales. Cause shrinkage technical happen because it is resistance and long cable from network voltagesecondary causes a voltage drop and their losses in the transformer, while non technical shrinkage happen because theft electricity and damages an on the app. PLN Area Bintaro has ashrinkage target amounting to 5,13%. On writing project end this tell about the calculation of technical losses in the Cipanas feeder. Cipanas feeders have 12 distribution substations with a feeder lenght of 14,89 kms. In the total calculation of technical shrinkage in Cipanas repeater obtained result of 537,95 kWH consisting of shrinkage at JTM of 100,44 kWH and shrink at distribution transformer equal to 437,51 kWH

Item Type: Thesis (Diploma)
Uncontrolled Keywords: shrinkage technical , non technical shrinkage , stans receipt susut teknis, susut non teknis, resistans
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 18 Feb 2026 07:09
Last Modified: 18 Feb 2026 07:40
URI: https://repository.itpln.ac.id/id/eprint/5089

Actions (login required)

View Item
View Item