CABRINY, MOENICA and Ispranyoto, Edy (2018) PENGARUH PEMBEBANAN DAN SUHU LINGKUNGAN TERHADAP SUSUT UMUR TRANSFORMATOR DISTRIBUSI. Diploma thesis, ITPLN.
MOENICA CABRINY 201571017.pdf
Restricted to Registered users only
Download (16MB)
Abstract
Transformator distribusi mempunyai peranan penting dalam penyaluran daya listrik dalam suatu sistem distribusi. Kerusakan pada transformator menyebabkan konstinuitas pelayanan terhadap konsumen akan terganggu (terjadi pemutusan aliran listrik atau pemadaman). International Electrotechnical Commission (IEC) 354 tahun 1972 menyatakan apabila transformator dibebani stabil pada daya pengenalnya dengan kondisi suhu sekitar 20°C, suhu hot spot transformator akan mencapai 98°C dan dikatakan bahwa susut umurnya akan normal. Semakin tinggi pembebanan akan mengakibatkan meningkatnya temperatur pada transformator, panas yang timbul dapat menyebabkan isolasi kumparan menjadi aus dan mempercepat proses penuaan. Oleh karena itu, kenaikan suhu ini harus dibatasi dan tingkat pembebanan harus diperhatikan untuk menjaga temperatur transformator agar tetap stabil dan tidak membuat laju pemburukan isolasi meningkat dengan suhu secara exponensial. Suhu sekitar tahunan kota Jakarta rata-rata adalah 31,61°C dengan pembebanan transformator di PT RCTI lebih besar dibandingkan pembebanan transformator di Media TV Indonesia. Hasil menunjukkan semakin tinggi tingkat pembebanan dan suhu lingkungan, membuat suhu hot spot akan semakin meningkat sehingga laju penauaan thermalnya juga semakin meningkat dan umur pemakaian transformator semakin berkurang.
Distribution transformer has a very cruicial role on electrical power supply distribution system. Demage to ther transformer cause continuity of service to consumers will be disrupted (electrical outages). In 1972, International electrotechnical commission (IEC) 354 claim if a transformer get a stable load on it’s identification power with ambient temperature 20°C,transformer hot spot temperature will reach 98°C. The higher the loading will result in an increase in temperature on the transformer, heat will cause the coil insulation to become demaged and accelerate the aging process. Therefore, this temperature rise should be limited and loading shall be taken into account to maintain the temperature of transformer in order to remain stable and not to make insulation deteriorates increases exponentially with temperature. Dailly average ambient temperature in Jakarta is 31,61°C with the loading of the transformer at PT RCTI is greater that transformer at Media TV Indonesia. The result show that the higher loading rate makes hot spot temperature will increase so that the rate of thermal aging is also increasing and the age of the transformator decreases.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | loss of life transformer, loading, hot spot temperature susut umur transformator, rating pembebanan, suhu lingkungan |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 18 Feb 2026 08:18 |
| Last Modified: | 18 Feb 2026 08:18 |