PRAMESTHI, PRATITA ARNI and Koerniawan, Tony (2018) PENGUJIAN TAHANAN ISOLASI DAN POLARIZATION INDEX MOTOR CONDENSATE PUMP UNIT 3 DI PLTU PT. INDONESIA POWER SEMARANG. Diploma thesis, ITPLN.
1. COVER PA.pdf
Download (61kB)
2. lembar pengesahan judul.pdf
Download (107kB)
7. abstrak - riwayat hidup.pdf
Restricted to Registered users only
Download (959kB)
Abstract
Motor listrik merupakan peralatan utama dalam sistem tenaga listrik yang berhubungan langsung dengan sistem pembangkitan tenaga listrik. Pada PLTU di PT. Indonesia Power Unit Pembangkitan Semarang terdapat beberapa motor listrik, salah satunya motor condensate pump yang termasuk sebagai komponen listrik untuk menjalankan sistem air kondesat dari hotwell menuju deaerator. Oleh karena itu, motor condensate pump dibutuhkan adanya preventive maintenance yaitu kegiatan pemeliharaan yang dilaksanakan secara berkala untuk mencegah terjadinya kerusakan peralatan secara tiba-tiba dan untuk mempertahankan unjuk kerja peralatan yang optimum sesuai umur teknisnya. Preventive maintenance pada motor condensate pump, salah satunya melakukan pengujian tahanan isolasi dan polarization index dari beberapa pengaruh gangguan yang terjadi misalnya short circuit, ground fault, dan arus bocor untuk mengetahui kondisi isolasinya agar tidak terjadi kegagalan pada motor condensate pump dan peralatan aman pada saat dioperasikan karena isolasi pada peralatan listrik adalah bagian yang sangat penting. Hasil pengujian tahanan isolasi yang didapat harus sesuai dengan standar IEEE 43-2000 yaitu minimal sebesar 100 MΩ dimana nilai tahanan isolasi digunakan untuk menghitung nilai polarization index pada motor condensate pump 3A dan motor condensate pump 3B.
The electric motor is the main equipment in the power system that are directly related to the power generation system. At the power plant in PT. Indonesia Power Generation Unit Semarang there are several electric motors, one condensate pump motors are included as a component of electricity to run the water system of a condensate of hotwell to the deaerator. Therefore, the condensate pump motors required the preventive maintenance that maintenance activities are conducted on a regular basis to prevent damage to the equipment suddenly and to maintain optimum equipment performance technical age appropriate. Preventive maintenance on condensate pump motors, one testing insulation resistance and polarization index of the some influence disturbance such as short circuit, ground fault, and leakage current to determine the condition of the insulation in order to avoid failure in the condensate pump motors and equipment safe when operated as insulation in electrical equipment is a very important part. Insulation resistance testing results obtained should be in accordance with the IEEE standard 43-2000 with the minimum insulation resistance is 100 MΩ where insulation resistance value is used to calculate the polarization index value on the condensate pump motor 3A and condensate pump motor 3B
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Insulation Resistance, Polarization Index, Condenser, Motor Condensate Pump Tahanan Isolasi, Polarization Index, Kondensor, Motor Condensate Pump |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 18 Feb 2026 08:26 |
| Last Modified: | 18 Feb 2026 08:26 |
| URI: | https://repository.itpln.ac.id/id/eprint/5098 |