SULAKSONO, ADHI and Koerniawan, Tony (2018) SETTING RELAY GANGGUAN TANAH PADA INCOMING DAN OUTGOING TERHADAP GROUNDING PENYULANG KARBIT DI GARDU INDUK PETUKANGAN. Diploma thesis, ITPLN.
ADHI SULAKSONO 201571021.pdf
Restricted to Registered users only
Download (2MB)
Abstract
Sistem proteksi tenaga listrik merupakan hal yang penting bagi sistem tenaga listrik baik untuk keandalan jaringan dan menjaga peralatan di sistem tenaga listrik supaya tidak rusak ketika ada arus gangguan baik itu arus gangguan hubung singkat antar fasa atau hubung singkat satu fasa ketanah. Sistem proteksi yang dibahas ini adalah sistem proteksi di outgoing feeder dengan menggunakan relay GFR dan menghitung arus ganguan satu fasa ke tanah untuk menetukan setting relay khususnya penyulang Karbit di Gardu Induk Petukangan. Setelah dilakukan perhitungan arus gangguan satu fasa ke tanah didapat arus gangguan terbesar ya itu 955,86 A dan arus gangguan terkecil 762,49 A dan dari perhitungan arus gangguan satu fasa ke tanah dapat disimpulkan bahwa semakin jauh dari sumber semakin kecil arus arus gangguannya dan semakin dekat dengan sumber maka arus gangguannya semakin besar. Adapun nilai TMS sebesar 0,1 dari hasil perhitungan dan 0,15 dari hasil pengujian.
System protection power electricity important thing for the system power electricity good for reliability network and keep equipment on the system bro electricity so that no no broken when there is current interference good that current interference connect short between phase or connect short one phase land . System protection discussed this is system protection in outgoing feeders with using the GFR relay and calculation current disturbance one phase to soil for determine setting relay in particular feeder in Petukangan substation. After done calculation current interference one phase to soil get it current interference biggest yes that's 955.86 A and current interference the smallest 762.49 A and from calculation current interference one phase to soil could in conclusion that increasingly far from source increasingly small current current interference and increasingly close with source then current interference increasingly great . As for TMS value is 0 , 1 from results calculation and 0.15 of results testing .
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | GFR, current short circuit one phase to ground GFR, arus gangguan hubung singkat satu fasa ke tanah |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |