KARTIKASARI, NOFI and suwarno, suwarno (2018) PENGGUNAAN RECLOSER DALAM PENGAMANAN ARUS LEBIH PENYULANG KDO02 GARDU INDUK KEDUNGOMBO. Diploma thesis, ITPLN.
SKRIPSI BAB 1 - 5.pdf
Restricted to Registered users only
Download (3MB)
Abstract
Sistem proteksi adalah suatu sistem pengaman terhadap peralatan listrik, lingkungan, dan sistem yang diakibatkan adanya gangguan teknis, gangguan alam, kesalahan operasi, dan penyebab lainnya. Pada sistem distribusi terdapat peralatan proteksi yang bertujuan untuk menjaga keandalan dari sistem distribusi tersebut. Diperlukan sebuah koordinasi proteksi agar peralatan peralatan tersebut dapat bekerja dengan optimal salah satu koordinasi proteksi yang dirancang adalah koordinasi antar PMT outgoing dengan recloser. Koordinasi ini bertujuan untuk mengamankan sistem distribusi dari gangguan baik itu gangguan antar phasa maupun gangguan phasa tanah. Pada koordinasi proteksi terdapat zona proteksi yaitu daerah yang diamankan masing-masing peralatan proteksi yang terpasang pada sistem distribusi. Namun, pada penyulang KDO02 mengalami penambahan daya pada trafo daya sehingga terdapat zona proteksi yang saling bertumpukan sehingga peralatan proteksi saling bekerja secara bersamaan dan hal ini dapat mengurangi kehandalan dari jaringan KDO02. Untuk mengembalikan kehandalan sistem distribusi di jaringan KDO02 maka diperlukan resetting pada peralatan proteksi agar zona proteksi antar peralatan proteksi saling terkoneksi dengan baik. Arus hubung singkat PMT Outgoing pada OCR=7184A, GFR=4409A. Tset recloser pada OCR=0.253s, dan GFR=0.6s. TMS PMT Outgoing pada OCR=0,28 GFR=0,36. TMS recloser pada OCR = 0,08, GFR=0,18.
Protection system is a safety system for electrical equipment, environment, and system caused by technical interferences, nature inteferences, operation error, and other cause. In the distribution system there are protection equipment that aims to maintain the reliability of the distribution system. A coordination of protection is required so that the equipment can work optimally, one of the coordination of the designed protection is the coordination between outgoing CB with the recloser. This coordination aims to secure the distribution system from interference. The interferences can between phases or ground to phase. In the protection coordination there is a protection zone that is the area secured by each protection equipment installed in the distribution system. However, the feeder of KDO02 experiences an additional power on the power transformer so that there is a mutual protection zone so that the protection equipment work simultaneously and this experiences can reduce the reliability of the feeder of KDO02. To restore the reliability of the distribution system in the KDO02 feeder, it is necessary to resetting on the protection equipment to protect the protection zone between the protection equipment. Short circuit current PMT Outgoing at OCR=7184A, GFR=4409A. The recloser tset at OCR=0,253s, and GFR=0,6s. Outgoing PMT TMS at OCR = 0,28, GFR = 0,36. TMS recloser at OCR=0,08, GFR=0,18.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | protection system, CB, Recloser, short circuit, OCR, GFR koordinasi proteksi, PMT, recloser, arus hubung singkat, OCR, GFR. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 18 Feb 2026 08:43 |
| Last Modified: | 18 Feb 2026 08:43 |
| URI: | https://repository.itpln.ac.id/id/eprint/5100 |