PURBAYANI, EKA ANGGRINI and Koerniawan, Tony (2018) PENGARUH PENGGANTIAN KELAS KETELITIAN CURRENT TRANSFORMER (CT) TERHADAP KESALAHAN RASIO ARUS PELANGGAN BERDAYA 197 KVA. Diploma thesis, ITPLN.
COVER PA.pdf
Download (38kB)
LEMBAR PENGESAHAN.pdf
Download (425kB)
BAB 1 - 5.pdf
Restricted to Registered users only
Download (4MB)
Abstract
Dengan pertumbuhan jumlah pelanggan potensial yang berada di wilayah kota Depok, maka kemungkinan semakin besar kerugian yang timbul akibat pengukuran energi pada pelanggan. Salah satu penyebab timbulnya kerugian karena adanya kesalahan rasio arus CT (Current Transformer) yang terpasang pada Kotak APP pengukuran tidak langsung. Perlu dilakukan pengujian kelas ketelitian pada CT untuk mengetahui batas kesalahan rasio arus yang diatur oleh standar PLN. Kemudian dilakukan penggantian kelas ketelitian pada CT untuk mengatasi masalah ini. Kegiatan ini dilakukan pada pelanggan PT. Astra Int Auto 2000 dengan mengganti kelas ketelitian CT dari 0,5 menjadi 0,5S. Terjadi perbandingan pengukuran antara kedua kelas yang berbeda. Maka pemahaman. Setelah dilakukan perhitungan selisih kesalahan rasio arus dari kedua CT yang terpasang bahwa terdapat energi yang tidak terukur oleh kWh meter. Besar nilai kWh inilah yang menjadi rugi-rugi atau losses untuk PT. PLN (Persero) Area Depok. CT sebagai salah satu alat bantu pengukuran (instrumentation) harus dirubah menjadi sebuah titik transaksi (point of transaction). Sehingga keuntungan pendapatan kWh merupakan orientasi bisnis yang mendasar bagi PLN dengan menekan sedikit mungkin kerugian energi (losses) yang terjadi di sistem pengukuran tersebut.
With the growing number of potential customers who are in the city of Depok, then the greater the possibility of losses resulting from energy measurements on the customer. One cause of the losses due to mistakes in flow ratio CT (Current Transformer) installed on APP Box indirect measurement. Necessary to test the CT accuracy class to determine the current ratio error limits set by the standard PLN. Then do the replacement on the CT accuracy class to resolve this issue. This activity is done at the customer PT. Astra Int Auto 2000 by replacing the CT accuracy class of 0.5 becomes 0,5S. There is a comparison of the measurement between the two different classes. Based on the results of tests performed, a decline in the current ratio error before and after the replacement of accuracy class. After calculating the error margin of the second flow ratio CT installed that are not measured by the energy meter. This Value kWh that is the losses to PT. PLN (Persero) Area Depok. So understanding CT as one of the tools of measurement (instrumentation) should be changed to a point of transaction (point of transaction). So that the revenue gains kWh a business orientation that is fundamental to PLN by pressing slightly possible energy losses (losses) that occur in the measurement system.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | CT, Error Flow Ratio, Accuracy Class, Losses CT, Kesalahan Rasio Arus, Kelas Ketelitian, Losses |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 19 Feb 2026 04:20 |
| Last Modified: | 19 Feb 2026 04:20 |
| URI: | https://repository.itpln.ac.id/id/eprint/5107 |