RAHMAN, MUHAMMAD ARIF and Hariyati, Rinna (2018) PENGUJIAN TAHANAN ISOLASI TRANSFORMATOR DISTRIBUSI FASA TIGA DI LABORATORIUM HUBUNG SINGKAT PT. PLN (PERSERO) PUSLITBANG KETENAGALISTRIKAN. Diploma thesis, ITPLN.
01. Cover.pdf
Download (150kB)
Lembar Pengesahan.pdf
Download (222kB)
6. Abstrak Bahasa Indonesia.pdf
Download (106kB)
7. Abstrak Bahasa Inggris.pdf
Download (109kB)
B1. BAB I Pendahuluan.pdf
Download (14kB)
B2. BAB II Pembahasan Teori Konsep.pdf
Download (306kB)
B3. BAB III Metode Penelitian.pdf
Restricted to Registered users only
Download (440kB)
B4. BAB IV Hasil dan Pembahasan.pdf
Restricted to Registered users only
Download (453kB)
B5. BAB V Penutup.pdf
Restricted to Registered users only
Download (180kB)
17. Daftar Pustaka.pdf
Download (99kB)
Abstract
Transformator merupakan suatu peralatan yang dapat mengubah tenaga listrik dari suatu level tegangan ke level tegangan lainnya. Transformator ini tentunya diharapkan dapat bekerja pada performa yang diinginkan. Oleh karena itu, sebelum transformator dapat digunakan pada sistem tenaga listrik, maka perlu dilakukan pengujian pada transformator distribusi tersebut. Pengujian transformator dilaksanakan menurut SPLN D3.002–1: 2007 dengan melalui pengujian yang diuraikan pada IEC 60076 yaitu: Salah satunya Pengujian Tahanan Isolasi dengan nilai tahanan isolasi sebesar tidak boleh kurang dari 2 GΩ., Pengujian Hubung Singkat dengan arus uji puncak Ipk 135 A ± 5% dan arus Irms 71 A ± 10%, Pengujian Impuls dengan bentuk gelombang waktu muka (T1= 0,84 µs – 1,56 µs) dan waktu ekor (T2= 40 µs – 60 µs), dengan tegangan uji impuls 125 kV, yang mana di maksud untuk mengetahui kekuatan tahanan isolasi transformator tersebut. Hasil pengujian dari tersebut nantinya untuk menentukan baik atau buruknya transformator tersebut. Setelah dinyatakan lulus uji, akan mendapatkan sertifikasi dari pihak pusat sertifikasi bahwa transformator tersebut layak digunakan pada sistem jaringan distribusi.
Transformer is an equipment that can convert electric power from a voltage level to another voltage level. This transformer is certainly expected to work on the desired performance. Therefore, before the transformer can be used in an electric power system, it is necessary to test the distribution transformer. Transformer testing is carried out according to SPLN D3.002-1: 2007 through the test described in IEC 60076, namely: One Isolation Resistance Test with an isolation resistance value of not less than 2 GΩ, Short Circuit Test with peak test current Ipk 135 A ± 5% and Irms 71 A ± 10% current, Impulse Testing with face time waveforms (T1 = 0.84 μs - 1.56 μs) and tail time (T2 = 40 μs - 60 μs), with an impulse test voltage of 125 kV, which is intended to determine the strength of the isolation of the transformer. The test results will later determine the good or bad of the transformer. After being declared passed the test, it will get certification from the certification center that the transformer is suitable for use in the distribution network system.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Transformer Distribution, SPLN D3.002–1: 2007 Transformator Distribusi, SPLN D3.002–1: 2007 |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 19 Feb 2026 05:20 |
| Last Modified: | 19 Feb 2026 05:20 |
| URI: | https://repository.itpln.ac.id/id/eprint/5111 |