PERHITUNGAN RUGI DAYA PADA JARINGAN DISTRIBUSI TEGANGAN RENDAH DI GARDU DISTRIBUSI PT. PLN (PERSERO) JAKARTA RAYA AREA MENTENG

NURHADIARTA, MUHAMMAD RIZKI and Tamam, Irvan Buchari (2018) PERHITUNGAN RUGI DAYA PADA JARINGAN DISTRIBUSI TEGANGAN RENDAH DI GARDU DISTRIBUSI PT. PLN (PERSERO) JAKARTA RAYA AREA MENTENG. Diploma thesis, ITPLN.

[thumbnail of Skripsi Rizki Nur Hadiarta (2015-71-049).pdf] Text
Skripsi Rizki Nur Hadiarta (2015-71-049).pdf
Restricted to Registered users only

Download (2MB)

Abstract

Sistem Distribusi Jaringan Tegangan Rendah merupakan saluran terdekat dengan konsumen tenaga listrik. Setiap konsumen pemakaian daya listrik tercatat di kWh meter masing masing, begitu juga untuk gardu distribusi besarnya pemakaian daya akan terlihat di kWh meter di gardu distribusi. Ketika terjadi kondisi dimana jumlah pemakaian daya di konsumen tidak sama dengan daya yang disalurkan oleh gardu distribusi, maka dalam hal ini timbul kerugian baik yang bersifat teknis maupun non teknis. Kerugian daya energi listrik di jaringan distribusi tegangan rendah di Gardu Distribusi dilihat dari segi teknisnya saja, kemudian memberikan solusi dari permasalahan yang ada. Metode yang di gunakan adalah perhitungan drop tegangan dan rugi-rugi daya. Luas jaringan, jenis penghantar, dan pembebanan sangat berpengaruh dalam penyaluran tenaga listrik, apabila luas jaringan dan jenis penghantar tidak memenuhi kebutuhan pembebanan maka akan timbul rugi daya dan susut tegangan yang akan mempengaruhi penyaluran energi listrik kepada konsumen dimana jika terjadi susut tegangan pada sistem distribusi maka energi listrik yang akan disalurkan kepada konsumen akan menjadi tidak standar lagi sesuai dengan SPLN No. 1;1995, dimana jatuh tegangan yang diperbolehkan dalam penyaluran distribusi hanya boleh sebesar 5% untuk jaringan udara, maka itu perlu adanya perhitungan dan penelitian untuk permasalahan jatuh tegangan, sehingga dalam penyampaian aliran listrik terhadap konsumen menjadi terpenuhi sesuai dengan standart yang telah ditetapkan.Setelah di lakukkan perhitungan pada salah satu gardu distribusi yaitu KN6B di dapat nilai drop tegangan sebesar RN: 5.847 V yaitu 2,25 %, SN:4.216 V yaitu 1,85 %, TN:5.121 V yaitu 2,22 % dimana hal ini cukup baik karena sesuai dengan batas standart +5% - 10% sesuai SPLN No. 1;1995, serta di dapat jumlah kerugian daya dalam 1 bulan sebesar 1085,456 kWh

Low Voltage Network Distribution System is the closest channel to electricity consumers. Every consumer of electricity consumption is recorded on each kWh meter, as well as for the substation the distribution of power consumption will be seen on kWh meters at the distribution substation. When conditions occur where the amount of power consumption in the consumer is not the same as the power supplied by the distribution substation, then in this case there is a loss both technical and non-technical. Electrical energy loss in the low voltage distribution network at the Distribution Station is seen from a technical point of view, then provides a solution to the existing problems. The method used is the calculation of voltage drop and power losses. The area of the network, the type of conveyor, and loading are very influential in the distribution of electricity, if the area of the network and the type of conveyor does not meet the need for loading, there will be a power loss and voltage loss which will affect the distribution of electrical energy to consumers where if the voltage shrinkage occurs in the distribution system electrical energy that will be distributed to consumers will become nonstandard according to SPLN No. 1; 1995, where the voltage drop allowed in distribution distribution may only be 5% for the air network, so it is necessary to calculate and research for the problem of voltage drop, so that the delivery of electricity to consumers becomes fulfilled in accordance with the established standards. in the calculation of one of the distribution substations, KN6B can get a voltage drop value of RN: 5,847 V which is 2,25%, SN: 4,216 V which is 1,85%, TN: 5,121 V which is 2,22% which is good enough because according to the standard limit + 5% - 10% according to SPLN No. 1; 1995, and a total of 1085,456 kWh of power losses in 1 month

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Distribution, voltage drop, unbalance load, power loss Distribusi, drop tegangan, ketidak seimbangan beban, rugi day
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 19 Feb 2026 06:45
Last Modified: 19 Feb 2026 06:45