ALVHIONIKA, RIRIN and Tamam, Irvan Buchari (2018) PENGARUH PENGGUNAAN DAN PENGUJIAN KUBIKEL AUTOMATIC CHANGE OVER PADA PELANGGAN PREMIUM UNTUK MEMINIMALISIR PEMADAMAN. Diploma thesis, ITPLN.
COVER.pdf
Download (170kB)
i lembar pengesahan.pdf
Download (201kB)
vi abstrak.pdf
Download (7kB)
vii Abstract.pdf
Download (86kB)
BAB 1.pdf
Download (98kB)
BAB 2.pdf
Download (484kB)
BAB 3.pdf
Restricted to Registered users only
Download (718kB)
BAB 4.pdf
Restricted to Registered users only
Download (1MB)
BAB 5.pdf
Restricted to Registered users only
Download (86kB)
Daftar Pustaka.pdf
Download (85kB)
Abstract
Meningkatnya taraf hidup masyarakat dan industri yang sangat pesat, mengharuskan PLN memberikan pelayanan suplai listrik secara terus menerus kepada konsumen. Namun kenyataan di masyarakat sering terjadi gangguan listrik karena suplai listrik yang hilang. Hal ini dapat mengganggu aktivitas kerja di tempat-tempat penting seperti rumah sakit, hotel, mall, wahana rekreasi dan daerah industri. Untuk itu digunakan alternatif penggunaan sistem Automatic Change Over (ACO) yang bekerja dengan dua sumber yang berbeda. jika sumber utama terganggu maka dengan waktu 0,3 detik akan pindah secara otomatis ke sumber cadangan. Penggunaan kubikel ACO dapat meningkatkan kehandalan pasokan listrik, dilihat dari hasil perbandingan sebelum dan setelah menggunakan kubikel ACO. Persentase perbandingannya yaitu pada gardu S44, S87, S38 dan P56 yaitu sebelum menggunakan kubikel ACO 23,25% 19,98% 16,83% dan 27,02% sedangkan setelah menggunakan kubikel ACO 42,85% 28,57% 28,57% dan pada gardu P56 persentase tidak ada.
Increasing the living standard of society and industry very rapidly, requires PLN to provide continuous supply of electricity to consumers. But the reality in the community often occurs power failure due to lost power supply. This can interfere with work activities in important places such as hospitals, hotels, malls, recreational rides and industrial areas. For it is used alternate use of Automatic Change Over system that works with two different source. If the primary source is interrupted then with 0.3 seconds the time will move automatically to the backup source. The use of ACO cubicles can improve teh reliability of power supplies, judging by comparison before and after using the ACO cubicles. The comparison percetage is at S44, S87, S38 and p56 that is before using ACO cubicle 23,25% 19,98% 16,83% dan 27,02% while after using ACO cubicle 42,85% 28,57 % 28,57% and in P56 substation there is no percentage.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Cubicle, Automatic Change Over , Installation Kubikel, ACO, Pemasangan |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 19 Feb 2026 07:02 |
| Last Modified: | 19 Feb 2026 07:02 |
| URI: | https://repository.itpln.ac.id/id/eprint/5129 |
