OPTIMALISASI RASIO TRANSFORMATOR ARUS TERHADAP SUSUT ENERGI PADA PELANGGAN TEGANGAN MENENGAH DI PT. PLN (PERSERO) AREA TANJUNG PRIOK

CAHYANI, YULIA YOLANDA and Pasra, Nurmiati (2018) OPTIMALISASI RASIO TRANSFORMATOR ARUS TERHADAP SUSUT ENERGI PADA PELANGGAN TEGANGAN MENENGAH DI PT. PLN (PERSERO) AREA TANJUNG PRIOK. Diploma thesis, ITPLN.

[thumbnail of Yulia Yolanda Cahyani.pdf] Text
Yulia Yolanda Cahyani.pdf
Restricted to Registered users only

Download (12MB)

Abstract

Transformator Arus merupakan suatu alat listrik yang mengubah tegangan arus bolakbalik dari satu tingkat ke tingkat yang lain melalui suatu gandengan magnet dan berdsarkan prinsip-prinsip induksi elektromagnet. Pemilihan trafo arus menjadi salah satu hal yang harus diperhatikan karena akan mempengaruhi hasil pengukuran. Kesalahan pemilihan trafo arus merupakan salah satu permasalahann yang menyebabkan terjadinya susut dalam proses pengukuran yang menimbulkan banyak kerugian, kerugian pada perusahaan maupun kerugian di pihak konsumen energi listrik. Salah satu cara mengatasi kesalahan pemilihan trafo arus adalah dengan pemilihan rasio trafo arus yang tepat. Proyek akhir ini membahas mengenai pemilihan rasio trafo arus terhadap susut energi pada sistem pengukuran di PT.PLN (Persero) Area Tanjung Priok. Arus nominal pada pelanggan dengan daya 10380 kVA adalah 300A, sehingga rasio trafo arus yang digunakan dengan rasio 300 pula. Susut energi pada pelanggan dengan daya kontrak 10380 kVA yang paling besar adalah yang menggunakan rasio trafo arus 350/5 dengan susut energi 28137,45895 kWh/bulan sedangkan susut energi yang paling kecil adalah yang menggunakan rasio trafo arus 300/5 dengan susut energi 27165,86231 kWh/bulan.

Current Transformer is an electrical device that converts the alternating current voltage from one level to another through a magnetic coupling and the principle of induction electromagnet. The selection of current transformer becomes one of the things that must be considered because it will affect the measurement results. Error selection of current transformer is one of the problems that cause the shrinkage in the process of measurement that caused a lot of losses, losses to the company and losses on the consumer electric energy. One way to overcome the error of selection of current transformer is by choosing the right current transformer ratio. This final project discusses the selection of current transformer ratio to the shrinkage of energy in the measurement system at PT.PLN (Persero) Tanjung Priok Area. The nominal current on the customer with power 10380 kVA is 300A, so the ratio of current transformer used with a ratio of 300 as well. The energy losses on customers with the largest 10380 kVA contract power are those using a current ratio of 350/5 currents with 28137.45895 kWh / month energy shrinkage while the smallest energy losses is using a current ratio of 300/5 with 27165 energy losses, 86231 kWh / month.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: energy losses, current transfrormer susut energi, trafo arus.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 19 Feb 2026 07:46
Last Modified: 19 Feb 2026 07:46
URI: https://repository.itpln.ac.id/id/eprint/5138