PENYEIMBANGAN BEBAN PADA GARDU MK226 PT. PLN (PERSERO) AREA CENGKARENG

RAHBIN, YANERI and Pahiyanti, Novi Gusti and Mangapul, Juara (2020) PENYEIMBANGAN BEBAN PADA GARDU MK226 PT. PLN (PERSERO) AREA CENGKARENG. Diploma thesis, ITPLN.

[thumbnail of PROYEK AKHIR YANERI RAHBIN (201571071).pdf] Text
PROYEK AKHIR YANERI RAHBIN (201571071).pdf
Restricted to Registered users only

Download (3MB)

Abstract

Dalam proses penyaluran tenaga listrik, terdapat susut atau sering disebut rugi rugi. Susut merupakan persoalan yang sering dihadapi olej PLN. Tingginya susut dapat merugikan konsumen maupun perusahaan itu sendiri yaitu PLN. Untuk mengurangi terjadi nya susut, pihak PLN pun melakukan penyeimbangan beban untuk memperkecil susut yang terjadi yaitu dengan memindahkan fasa rumah pelanggan yang telah di tentukan dari hasil pengukuran dan perhitungan ke fasa yang lain untuk mengurangi ketidak seimbangan beban pada jurusan 1. Sebelum dilakukan penyeimbangan beban nilai rugi-rugi pada jurusan 1 32% atau susut yang dihasilkan sangatlah besar yaitu 185,54 Watt. Dari hasil tersebut dapat dilihat perbandingan sebelum pemerataan dan setelah pemerataan. Dan setelah dilakukannya penyeimbangan beban rugi-rugi pun menurun yaitu sebebsara 11,7% dan susut pun ikut menurun yaitu menjadi 42,91 Watt. pemerataan ini dianggap berhasil karena kriteria rugi-rugi atau susut yang telah di dapat setelah penyeimbangan senilai 11,7% jauh dibawah kriteria yang di tetapkan oleh PT.PLN (persero) area Cengkareng yaitu 15% .

In the process of electricity distribution, available shrinkage or often called losses. Losses discussions often discussed by PLN. The high Losses can be detrimental to consumers or the company itself, namely PLN. To reduce losses occur, the PLN also performs a load balancing to reduce losses that occur that is by changing the phase of the customer's home that has been determined from the measurement results and calculating it to another phase to reduce the imbalance of costs in majors 1. Before carrying out the burden of the burden of loss -the loss in majors 1 32% or the resulting shrinkage is greater that is 185.54 Watt. From these results can be seen before equalization and after equality. And after borrowing the balance, the burden of losses decreased by 11.7% and the losses also decreased, namely to 42.91 Watt. This examiner was considered successful because the criteria of reporting that had been obtained after balancing the value of 11.7% were far below the criteria set by PT. PLN (Persero) Cengkareng area which was 15%.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Energy Shrinkage, Load Balancing, Criteria Susut energi, Penyeimbangan Beban, Kriteria