PENGUJIAN METERING TRANSFORMATOR ARUS 20 kV DI GARDU DISTRIBUSI TIPE BETONPENGUJIAN METERING TRANSFORMATOR ARUS 20 kV DI GARDU DISTRIBUSI TIPE BETON

MUTIA, MUTIA and Ispranyoto, Edy (2019) PENGUJIAN METERING TRANSFORMATOR ARUS 20 kV DI GARDU DISTRIBUSI TIPE BETONPENGUJIAN METERING TRANSFORMATOR ARUS 20 kV DI GARDU DISTRIBUSI TIPE BETON. Diploma thesis, ITPLN.

[thumbnail of MUTIA 2015-71-094.pdf] Text
MUTIA 2015-71-094.pdf
Restricted to Registered users only

Download (2MB)

Abstract

Transformator arus merupakan salah satu instrument yang mentransformasikan dari arus yang besar ke arus yang kecil guna pengukuran dan proteksi. Pengujian transformator arus adalah pengujian yang dilakukan untuk mengetahui apakah trafo arus masih layak digunakan atau sudah tidak layak digunakan. Pada transformator arus kali ini membahas metering atau pengukuran pada transformator untuk mengetahui arus maksimal pada transformator yang bisa menyebabkan kejenuhan transformator arus dan kesalahan arus pada CT. Di PT.PLN (Persero) Area Bintaro dalam pengujian transformator arus sudah menggunakan CT Analyzer Omicron. Dengan menggunakan metode kuantitafif dan dilakukan pengujian hasil perhitungan pada CT tersebut arus yang mengalir pada sisi sekunder dan sisi primer di PT.Samyang adalah 126,3 A dan 1010,4 A, di PT.Jasamarga Properti adalah 99,46 A dan 198,9 A dan pada PT.Indograveur adalah 341,35 dan 6827 A. Jadi, batas arus maksimal yang mengalir pada rangakain sekunder dan primer jika hasilnya lebih dari batasnya maka transformator arus (CT) tersebut mulai jenuh. Dan kesalahan arus yang di dapatkan masih dalam keadaan aman karena tidak melewati batas yang ditentukan yaitu 0,25%. .

Current transformer is one instrument transformer that transforms from a large current to a small current for measurement and protection. To find out the condition of the current transformer is still feasible to use or not, it is necessary to conduct testing. The test uses the Omicron CT Analyzer. CT Omicron Analyzer is a device that is capable of testing current transformers and displaying automatically such as ratios, angle shifts, and others. After that do the calculations to find out the saturation of the current transformer and the current error after testing, to find out it's still worth using or not. After testing the result of calculation on the CT current flowing on the secondary and primary side at PT.Samyang is 126,3 A and 1010,4 A, at PT.Jasamarga Properti is 99,45 A and 198,9 A and at PT.Indograveur is 341,35 A and 6827 A. So the maximum current limit that flows in the secondary and primary circuit if the result is more than the limit, the current transformder begins to saturate. And current errors that are still obtained in a safe conditions because it does not exceed the specified limit 0,25%.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Current Transformer, Measurement, Testing. Transformator Arus, Pengukuran, Pengujian.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 20 Feb 2026 01:11
Last Modified: 20 Feb 2026 01:11
URI: https://repository.itpln.ac.id/id/eprint/5145