MENGURANGI TRIP PENYULANG DAN MEMINIMALISIR ENERGI YANG TIDAK TERJUAL DENGAN SISTEM PEMELIHARAAN PREVENTIF DI PT PLN (PERSERO) DISTRIBUSI JAWA BARAT AREA BANDUNG

NURJAMAN, NURJAMAN and Hariyati, Rinna (2018) MENGURANGI TRIP PENYULANG DAN MEMINIMALISIR ENERGI YANG TIDAK TERJUAL DENGAN SISTEM PEMELIHARAAN PREVENTIF DI PT PLN (PERSERO) DISTRIBUSI JAWA BARAT AREA BANDUNG. Diploma thesis, ITPLN.

[thumbnail of 1. Cover PA.pdf] Text
1. Cover PA.pdf

Download (12kB)
[thumbnail of 2. Pengesahan 1.pdf] Text
2. Pengesahan 1.pdf

Download (2MB)
[thumbnail of 3. ABSTRAK & DAFTAR ISI.pdf] Text
3. ABSTRAK & DAFTAR ISI.pdf

Download (177kB)
[thumbnail of 4. BAB I juli 13.pdf] Text
4. BAB I juli 13.pdf

Download (96kB)
[thumbnail of 5. BAB II  15 juli.pdf] Text
5. BAB II 15 juli.pdf

Download (390kB)
[thumbnail of 6. BAB III 5 mei.pdf] Text
6. BAB III 5 mei.pdf
Restricted to Registered users only

Download (672kB)
[thumbnail of 7. BAB IV 30 MEI fix.pdf] Text
7. BAB IV 30 MEI fix.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of 8. BAB V 01 JUNI.pdf] Text
8. BAB V 01 JUNI.pdf
Restricted to Registered users only

Download (87kB)
[thumbnail of 9. DAFTAR PUSTAKA.pdf] Text
9. DAFTAR PUSTAKA.pdf

Download (87kB)

Abstract

Sistem tenaga listrik tidak bisa lepas dari berbagai macam gangguan listrik yang dapat mengganggu kualitas dan kuantitas pelayanan pasokan listrik. Untuk mengurangi pemadam yang terjadi di PT PLN (Persero) Distribusi Jawa Barat Area Bandung akibat dari gangguan trip penyulang, sehingga dilakukan pemeliharaan preventif pada setiap penyulang untuk mengatasi gangguan tersebut. Tahun 2015 gangguan yang terjadi sebanyak 556 kali, dan tahun 2016 gangguan meningkat sebesar 24,6% dengan jumlah gangguan 693 kali, dan tahun 2017 gangguan yang terjadi mengalami penurunan sebesar 61,5% dengan gangguan sebanyak 265 kali. Pada tahun 2015 dan 2016, gangguan yang terjadi melebihi batas maksimal,. maka perlu penekanan tahun 2015 30,94%, dan 2016 80%. namun tahun 2017 gangguan yang terjadi 30,99% di bawah dari batas maksimal gangguan. Presentase kerugian materi dari beberapa penyulang yang sering mengalami gangguan trip penyulang diantaranya ; penyulang CGDG, CHM, CPDU, CTP, PLSI, KMO, UZC, dan UGB. Pada tahun 2015 ke 2016 presentase penurunan sebesar 60,4%, dan tahun 2016 ke 2017 sebesar 92,54%. Presentase penurunan pada tahun 2016 ke 2017 lebih besar penurunannya. Karena pada tahun 2015 kagiatan pemeliharaan preventif dilakukan pada beberapa penyulang saja. Sedangkan tahun 2016 kegiatan pemeliharaan preventif dilakukan pada semua penyulang.

Electricity system can’t be separeted from various kinds of electrical disturbances that can interfere with the quality and quantity of electrical supply services. In order to reduce the extinction that occurred in PT PLN (Persero) West Java Distribution Area Bandung due to disruption of feeder preventative maintenance should be done. In 2015 the disturbance was occurred was 556 times, in 2016 the interference increased by 24.6% with the number of disturbance 693 times, and in 2017 the disturbance that occurred decreased by 61.5% with the numbers occurred 265 times. In 2015 and 2016, disruptions that occurred, exceeds the maximum limit. In order to surpress the disruptions 30.59% of disturbance suppression is made by 2015 and 80% by 2016. but, in the 2017 the disruption that occurs was 30.99% below the maximum limit of disruptions. Some feeders who often experience interruption of the feeders trips are; CGDG, CHM, CPDU, CTP, PLSI, KMO, UZC, and UGB feeder. In 2015 to 2016 the decrease percentage of disruptions was 60.4%, and 2016 to 2017 amounted to 92.54%. The decrease in disturbance percentage in 2016 to 2017 is greater than in 2015-2016.That happened because in 2015 preventive maintenance activities are only done on some feeders only. While the year 2016 preventive maintenance activities carried out on all feeders

Item Type: Thesis (Diploma)
Uncontrolled Keywords: feeders disruption, preventive maintenance, percentage of energy not sale. gangguan trip penyulang, pemeliharaan preventif, persentase gangguan energi tidak terjual.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 20 Feb 2026 01:46
Last Modified: 20 Feb 2026 01:46
URI: https://repository.itpln.ac.id/id/eprint/5156