KURNIAWAN, ARIOSKA YUSRI and suwarno, suwarno (2018) KOORDINASI PROTEKSI ARUS LEBIH PADA TRANSFORMATOR TENAGA DI GARDU INDUK MILLENIUM 150/20 KV. Diploma thesis, ITPLN.
0. ARIOSKA.(201571095).PROYEKAKHIR.pdf
Restricted to Registered users only
Download (4MB)
7. Abstrak Bahasa Indonesia.pdf
Download (230kB)
8. Abstrak Bahasa Inggris.pdf
Download (228kB)
Abstract
Dalam rangkaian listrik gangguan yang paling sering terjadi yaitu gangguan terhadap arus lebih yang mengakibatkan nilai arus melebihi batas maksimal pada sistem dan alat tersebut, sehingga tegangan menjadi turun. Maka dari itu dibutuhkan proteksi pada rangkain listrik terhadap arus lebih tersebut yaitu over current relay merupakan alat relai yang bekerja terhadap arus lebih. Gardu induk sebagai alat penghubung listrik dari jaringan transmisi ke jaringan distribusi primer yang memiliki banyak komponen listrik, maka dalam penyaluran tersebut haruslah berjalan dengan lancar, aman dan handal, karena pada gardu induk memiliki komponen yang sangat banyak untuk dilindungi didalamnya seperti penyulang, busbar, serta transformator tenaga sehingga dibutuhkan banyak proteksi terhadap masing-masing daerah yang harus dilindungi. Proteksi arus lebih atau pengaman arus lebih banyak terdapat di rangkaian-rangkain listrik, proteksi itu sendiri bekerja tergantung dari arus gangguan di masing-masing. Proteksi ini dapat memberikan kerja pada pemutus tenaga apabila terjadi gangguan sehingga gangguan tidak meluas. Namun dalam melakukan pengaman terhadap sisi-sisi di gardu induk dilakukan terhadap sisi hilir yang lebih rendah yaitu pada penyulang hingga ke busbar dan transformator tenaga yang merupakan komponen utama pada gardu induk dalam melakukan penyaluran tenaga listrik. Agar tidak terjadi dahulu dan mendahulu antar relai arus lebih terhadap gangguan yang terjadi yang dapat berakibat kegagalan relay yang bekerja maka perlu dilakukan koordinasi di tiap tiap relai yang terpasang dimulai dari sisi hilir (penyulang) hingga ke sisi hulu (transformator tenaga) agar gangguan tidak meluas kedaerah yang lebih hulu, maka nilai koordinasi ini dibutuhkan nilai waktu tunda, sehingga waktu tunda pada pada koordinasi proteksi ini dari sisi hilir ke hulu yaitu 0.23 s, 0.4 s, 0.8 s, 0,57 s dengan nilai Tms 0.1, 0.23, 0.24, 0.34. sehingga Dalam proyek akhir ini membahas hal-hal yang perlu diperhatikan dalam penyetelan relai dan koordinasinya yaitu pada nilai penyetelan arus dan pemberian waktu tunda di tiap-tiap relai agar tidak saling dahulu dan mendahulu dimasing-masing relai (koordinatif).
In an electric circuit interference occurs most often to the interference resulting in a over current value exceeding the maximum on the system and the device, so voltage declined. So is required protection in chain electricity to the over current are over current relay is a relay woring against the over current. Gardu Induk as a means of a system of liaison electricity transmisin to primary distribution system that had a lot of electrical components, hence in the distribution should run smoothly, safe and reliable. Because in Gardu Induk having component parts very much ike to be protected by feeders, busbars, and transformer power that it takes a lot afo protection against any area the to be covered. Protection over current are plenty in electricity chain, protection tha is work hanging from the current disorder in areas. Protection can provide in a breaker (PMT) when power of disruption, so that the disease has not spread. But in going in safety against the gardu induk done against the side of early on to are busbars, feeders, and transformer power that constitutes the principal component gardu induk in conducting the distribution of electric power. To avoid possible racin between relai current to interference that occurs who to get failure relay who works we need to coordination in every relay to which it is attached started from the early (feeder) to side the end (transformer power) that interference has not spread to the areas a transformer power, Then valuation coordination is needed the time value of a delay, So that protection coordination delay on at the feeder until transformation power are 0.23 s, 0.4 s, 0.8 s, 0,57 s dengan nilai Tms 0.1, 0.23, 0.24, 0.34. So in the finished project discussed issues that need to be given attention to in setting relai and the coordination that is in the value of the stream and the provision of setting over current and delay in every relay each other so that they do not used to each other in each of the relay (coordinative).
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Over current relay, transformer power, interference of over current Relai arus lebih, transformator tenaga, gangguan arus lebih |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 20 Feb 2026 07:36 |
| Last Modified: | 20 Feb 2026 07:36 |
| URI: | https://repository.itpln.ac.id/id/eprint/5164 |