DANGKUA, PRAHMA and Widyastuti, Christine (2018) LAYANAN PREMIUM TEGANGAN RENDAH PADA PT. FNR DENGAN DAYA 158 kVA DI PT. PLN (PERSERO) AREA PONDOK KOPI. Diploma thesis, ITPLN.
PRAHMA DANGKUA.pdf
Restricted to Registered users only
Download (3MB)
Abstract
Dalam menjalankan fungsi maupun produksinya dalam sebuah pabrik atau industri, seperti pelanggan pada PT. PLN (Persero) Area Pondok Kopi merupakan perusahaan yang fokus bergerak di bidang manufacturing molding injeksi untuk plastik dan karet tentunya memerlukan energi listrik yang bekerja secara kontinu dan demi terhindar dari rusaknya peralatan, maka perusahaan tersebut berlangganan premium tegangan rendah jenis silver dengan daya 158 kVA sehingga pelanggan termasuk jenis golongan tarif dasar listrik I-2 industri sedang, yang mendapat tenaga listrik dari Gardu Induk Penggilingan dan dua gardu distribusi yaitu gardu PG 403 yang terdapat pada penyulang kualitas dan gardu distribusi PGL 39 yang terdapat pada penyulang ampul dan satu jurusan khusus pada PHB-TR di masing-masing gardu dengan menggunakan Automatic Change Over sebagai saklar pemindah jika terjadi gangguan di salah satu pasokan listrik. Dalam mendistribusikan energi listrik tentunya kualitas pelayanan dituntut untuk stabil jadi perlu diperhatikan pola pembebanan pada transformator distribusi, dimana dalam analisa pembebanan trafo pada PG 403 persentase trafo sebesar 68,75% dan pada PGL 39 8,92% jadi dapat dikatakan kualitas pendistribusian dari segi pembebanan sangat baik.
In carrying out its functions and production in a factory or industry, such as customers at PT. PLN (Persero) Pondok Kopi Area, a company that focuses on manufacturing injection molding for plastics and rubber certainly requires electrical energy that works continuously and in order to avoid damage to equipment, the company subscribes to premium low voltage silver type with a power of 158 kVA so that customers are included in the type of basic electricity tariff I-2 medium industry, which gets electricity from the Penggilingan substation and two distribution substations, namely the PG 403 substation contained in the quality feeder and the PGL 39 distribution substation contained in the ampul feeder and one special line in the PHB-TR in each substation by using an Automatic Change Over as a transfer switch in the event of a fault in one of the electricity supplies. In distributing electrical energy, the quality of service is required to be stable, so it is necessary to pay attention to the loading pattern of the distribution transformer, where in the analysis of transformer loading at PG 403 the transformer percentage is 68.75% and at PGL 39 it is 8.92%, so it can be said that the quality of distribution in terms of loading is very good.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Pelanggan Premium Tegangan Rendah, Automatic Change Over, Pembebanan Transformator Distribusi. premium low voltage customers, Automatic Change Over, Distribution Transformers |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 20 Feb 2026 08:14 |
| Last Modified: | 20 Feb 2026 08:14 |
| URI: | https://repository.itpln.ac.id/id/eprint/5166 |