Diansyah, Hery and Brunner, I Made Indradjaja Marcus and Rosyadi, Marwan (2025) Analisis Anomali Pengukuran kWh Meter Utama dan meter Pembanding Konsumen KCIC GIS PONCOL BARU II. Masters thesis, IT PLN.
TESIS_HERYDIANSYAH.pdf
Restricted to Registered users only
Download (4MB)
Abstract
Besaran arus dan tegangan yang diterima sangat mempengaruhi kinerja kWh meter. Kesalahan pengukuran dapat terjadi karena ketidaksesuaian nilai arus atau tegangan yang dapat menyebabkan perbedaan antara pengukuran meter utama dan pembanding. Hal ini dapat menyebabkan terjadinya dispute kedua pihak yang bertransaksi. Dengan menggunakan meter konsumen sebagai acuan yang dianggap valid, penelitian ini bertujuan untuk mengindentifikasi penyebab terjadinya kesalahan pengukuran sehingga terjadi deviasi antara pembacaan pada meter utama dengan meter pembanding. Selain observasi langsung di lapangan, sistem Reading Meter Automatic (AMR) digunakan untuk mengumpulkan data load profile, dan metode Z-test statistik digunakan untuk menganalisisnya. Metode penelitian ini mencakup cara mengkaji dan menelaah teori-teori pendukung, pengujian dan observasi dilapangan serta diskusi dengan pihak-pihak terkait. Hasil penelitian menunjukan bahwa penyebab deviasi pembacaan mengarah pada kesalahan rangkaian wiring di kWh meter ketika suplai dari GIS Sumarecon Bekasi II kwh meter utama dan pembanding menunjukan pembacaan bernilai konstan ± 1600 kwh. Dari pengukuran pertama ditemukan bahwa ada energi yang tercatat namun indikasi error data constant. Dari hasil Ztest didapatkan hasil probabilitas > 0,05 = tolak H0. pembacaan meter utama dan meter pembanding masih terdapat perbedaan signifikan. terdapat pergeseran fasa pada rangkaian VT dimana cos phi mendekati 1 ketika suplai dari GIS Summarecon Bekasi II atau line KCIC pada GIS Poncol Baru II tidak berbeban Dilakukan perbaikan pada tanggal 7 Agustus 2024. Sehingga pembacaan cosphi berubah dari 0,86 menjadi -0,076 dan sudut antara arus dan tegangan mendekati 90° dan pembacaan beban mendekati nol “0” dan pihak yang bertransaksi tidak mengalami dispute.
The kWh meter's performance is significantly impacted by the amount of current and voltage received. Differences between the primary meter's and the reference meter's readings may be the result of measurement mistakes brought on by variations in current or voltage levels. Conflicts between the two parties to the transaction may result from this. This study attempts to determine the reasons behind measurement mistakes that lead to discrepancies between the readings on the main meter and the comparison meter by using the consumer meter as a reference that is deemed valid. In addition to direct field observations, load profile data is gathered using the Automatic Meter Reading (AMR) system and analyzed using the statistical Z-test approach. This research methodology involves doing field experiments and observations, reviewing and analyzing supporting theories, and having conversations with pertinent parties. When the supply from GIS Sumarecon Bekasi II main and comparison kWh meters gives a steady reading of about ± 1600 kWh, the research findings demonstrate that the reading deviation is caused by a wiring circuit mistake in the kWh meter. Energy was detected in the first measurement, but there was also an indication of ongoing data inaccuracy. A probability result of > 0.05 was obtained from the Z-test outcomes, meaning that H0 was rejected. The readings from the comparison meter and the main meter still differ significantly. When the KCIC line at GIS Poncol Baru II or the supply from GIS Summarecon Bekasi II is unloaded, there is a phase shift in the VT circuit where the power factor gets closer to 1. The repairs took place on August 7, 2024. As a result, there being no disagreement between the participants in the transaction, the cosphi reading went from 0.85 to 0.95, indicating a marked improvement in efficiency. This adjustment not only enhances the overall performance of the system but also suggests that further optimization may be possible with additional monitoring and fine-tuning 0.86 to -0.076, the angle between the current and voltage approached 90°, and the load reading was getting close to zero, or "0." and the transacting parties did not experience a dispute
| Item Type: | Thesis (Masters) |
|---|---|
| Uncontrolled Keywords: | kWh meter, AMR, Z-test, wiring, current, voltage kWh meter, AMR, Z-test, wiring, arus dan tegangan. |
| Subjects: | Bidang Keilmuan > Teknik Elektro Thesis |
| Divisions: | Pasca Sarjana > S2 Teknik Elektro |
| Depositing User: | Sutrisno |
| Date Deposited: | 23 Feb 2026 06:40 |
| Last Modified: | 24 Feb 2026 02:10 |
| URI: | https://repository.itpln.ac.id/id/eprint/5173 |