PENGGUNAAN CIRCUIT BREAKER OUTGOING DALAM MENINGKATKAN KEANDALAN SISTEM PENYALURAN TENAGA LISTRIK

RACHMAN, SINUNG ABI and Paryoto, Djoko (2017) PENGGUNAAN CIRCUIT BREAKER OUTGOING DALAM MENINGKATKAN KEANDALAN SISTEM PENYALURAN TENAGA LISTRIK. Diploma thesis, ITPLN.

[thumbnail of SINUNG ABI RACHMAN (201471015).pdf] Text
SINUNG ABI RACHMAN (201471015).pdf
Restricted to Registered users only

Download (3MB)

Abstract

Dalam suatu sistem Penyaluran tenaga listrik khususnya pada saluran kabel tegangan menengah tentunya tidak luput dari gangguan – gangguan yang terjadi, dengan gangguan yang sering terjadi akan merusak peralatan Seperti : trafo, penghantar, isolasi maupun peralatan hubung. Di kawasan Mega kuningan dengan pelanggan Tegangan Menengah yang cukup banyak, perlu adanya prioritas dalam hal keandalan, Apabila terjadi pemadaman distribusi tenaga listrik ke pelanggan yang sering terjadi maka kontinuitas distribusi listrik kurang baik. Gangguan yang terjadi pada Gardu Utama bisa saja disebabkan oleh kurangnya proteksi/pembatas pada gardu distribusi konsumen khusus yang tidak dapat berfungsi sebagaimana mestinya apabila terjadi gangguan. Maka apabila gardu utama sampai trip sehingga akan mengakibatkan semua gardu distribusi pada penyulang tersebut padam, serta dapat mengganggu penyaluran tenaga listrik kepada konsumen lainnya karena timbulnya pemadaman. Dengan sangat pentingnya sistem proteksi tersebut maka perlu adanya penambahan penggunaan Circuit Breaker Outgoing pada gardu distribusi. Pada bab 4 pembahasan yang dibahas angka padam yang terjadi pada kawasan Mega Kuningan yaitu 91 kali dari periode Januari sampai Agustus dan setelah adanya Circuit Breaker Outgoing angka padam turun menjadi 59 kali.

In a power distribution system especially on medium voltage cable channel, certainly it’s not spared from interferences, interferences that often occurred can damage tools like: transformer, conductor, isolator and even connecting tools.In the area of Mega brass with customers of Medium Volume is quite a lot, need a priority in terms of reliability, In case of power outage distribution to the customer that often happens then the continuity of electricity distribution is less good. The disturbance that occurs in the main substation could be caused by the lack of protection / limitation on a special consumer distribution substation that can not function properly in case of interference. So if the main substation to trip so it will result in all the distribution substations on the repeater is extinguished, and can disrupt the distribution of electricity to other consumers due to the emergence of blackouts. With the importance of the protection system it is necessary to add the use of Circuit Breaker Outgoing on distribution substations. On Bab 4 Discuss of discussion the number of outages that occurred in the area of Mega Kuningan is 91 times from January to August and after the Circuit Breaker Outgoing the number went down to 59 times.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Circuit Breaker Outgoing (CBO), Distribution System Reliability, Protection System. Circuit Breaker Outgoing (CBO),Keandalan Sistem Distribusi, Sistem Proteksi.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 23 Feb 2026 13:29
Last Modified: 23 Feb 2026 13:29
URI: https://repository.itpln.ac.id/id/eprint/5191