ZERO DOWN TIME DENGAN SISTEM DISTRIBUSI LOOP DI MEGA KUNINGAN

WIDYAPUTRI, NABILA AZMI and suwarno, suwarno (2017) ZERO DOWN TIME DENGAN SISTEM DISTRIBUSI LOOP DI MEGA KUNINGAN. Diploma thesis, ITPLN.

[thumbnail of PA Cover.pdf] Text
PA Cover.pdf

Download (74kB)
[thumbnail of lemb pengesahan001.pdf] Text
lemb pengesahan001.pdf

Download (28kB)
[thumbnail of PA i-v.pdf] Text
PA i-v.pdf

Download (100kB)
[thumbnail of PA revisi setelah sidang.pdf] Text
PA revisi setelah sidang.pdf
Restricted to Registered users only

Download (929kB)
[thumbnail of PA daftar pustaka.pdf] Text
PA daftar pustaka.pdf

Download (66kB)

Abstract

Dengan semakin pentingnya peranan tenaga listrik dalam kehidupan sehari-hari, maka kontinyuitas penyediaan tenaga listrik juga menjadi tuntutan yang semakin besar dari konsumen tenaga listrik. Oleh karena hal tersebut, maka dituntut adanya suatu sistem tenaga listrik yang handal. Dengan adanya Zero Down Time diharapkan dapat meningkatkan kualitas pasokan energi listrik kepada pelanggan mengingat konsumsi energi listrik. Dengan menerapkan sistem distribusi Loop pasokan energi listrik dapat terus tersalurkan mengingat sistem ini disuplai oleh lebih dari satu penyulang Dalam hal ini jika salah satu penyulang mengalami kesalahan atau pemeliharaan, distributor loop masih dapat dipasok oleh penyulang lain yang terhubung. Dengan cara ini pasokan ke konsumen tidak terpengaruh bahkan ketika penyulang tidak bekerja.

With the growing importance of the role of electric power in everyday life, the continuity of the supply of electricity is also a growing demand of electricity consumers. Therefore, it requires a reliable electric power system. With the Zero Down Time is expected to improve the quality of electricity supply to customers considering the consumption of electrical energy. By applying the distribution system the Loop of the supply of electrical energy can continue to be channeled given that the system is supplied by more than one repeater In this case if one of the feeders is faulty or maintenance, the loop distributor can still be supplied by another connected feeder. In this way the supply to the consumer is not affected even when the repeater does not work.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Loop Distribution System, Zero Down Time Component Sistem Distribusi Loop, Komponen Zero Down Time
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 23 Feb 2026 13:41
Last Modified: 23 Feb 2026 13:41
URI: https://repository.itpln.ac.id/id/eprint/5193