ARIFN, MULFAINNAH NUR and Siregar, M Syukur (2017) PENARIKAN KABEL TANAH DARI GARDU INDUK CAWANG KE GARDU DISTRIBUSI K210. Diploma thesis, ITPLN.
1. cover.pdf
Download (46kB)
2. Lembar Pengesahan.pdf
Download (180kB)
7. Abstrak.pdf
Download (259kB)
8. Abstrack.pdf
Download (53kB)
10. Isi.pdf
Restricted to Registered users only
Download (1MB)
11. Daftar Pustaka.pdf
Download (88kB)
Abstract
Teknik pemasangan kabel tanah terdiri dari kabel tanam langsung, kabel dengan menggunakan duct maupun kabel dengan persilangan, namun pada proyek akhir ini digunakan tanam langsung karena kebutuhan dilapangan yang cocok digunakan adalah kabel tanah tanam langsung. Kabel tanah yang dipergunakan pada saat pemasangan adalah tipe Three core NA2XSEYBY 3 x 240 mm2 . Penggunaan kabel jenis ini diharapkan agar setiap saluran 3 fasa pada suhu normal yaitu 30 ℃. Hasil pengujian partial discharge berada pada level 1 dengan nilai pengukuran dibawah 1, hasil pengujian arus bocor yang didapatkan juga baik yaitu hanya sebesar 0,03 mA dan hasil uji tahanan isolasi nilai tahanan isolasi yang berbeda-beda bukan suatu masalah karena semakin besar tahanan isolasi pada suatu kabel maka semakin baik juga kualitas kabel yang telah dilakukan terminasi. Dari hasil pengujian dapat dikatakan kabel yang dipasang mengikuti setiap proses dengan baik sehingga kabel tersebut dapat dikatakan layak operasi.
Ground cabling technique consists of direct planting cable, cable using duct or cable with a cross, but in this final project used direct planting because the needs of the field that is suitable to use is a direct land planting cable. The ground cable used at the time of installation is Three core NA2XSEYBY type 3 x 240. The use of this type of cable is expected for every 3 phase channel at normal temperature 30 ℃. Partial discharge test results are at level 1 with the measurement value below 1, the leakage current test results are also good that is only 0.03 mA and the results of insulation resistance test results of different isolation resistance values is not a problem because the greater the insulation resistance at a cable then the better is also the quality of cable that has been done termination. From the test results can be said that the cable is installed to follow each process well so that the cable can be said to be feasible operation.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | ground cables, mounting, testing. kabel tanah, Pemasangan, pengujian. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 23 Feb 2026 13:47 |
| Last Modified: | 23 Feb 2026 13:47 |
| URI: | https://repository.itpln.ac.id/id/eprint/5194 |
