Pengawasan MCB DC Pada Kubikel 20 KV Di Gardu Induk Denai Sumut

SINURAT, ARNOLD FERNANDO and Pasra, Nurmiati (2017) Pengawasan MCB DC Pada Kubikel 20 KV Di Gardu Induk Denai Sumut. Diploma thesis, ITPLN.

[thumbnail of COVER.pdf] Text
COVER.pdf

Download (67kB)
[thumbnail of lembar pengesahaan, Abstrak, dan Daftar Isi.pdf] Text
lembar pengesahaan, Abstrak, dan Daftar Isi.pdf

Download (113kB)
[thumbnail of Bab 1, Bab 2, Bab 3.pdf] Text
Bab 1, Bab 2, Bab 3.pdf
Restricted to Registered users only

Download (438kB)
[thumbnail of Bab 4 proyek akhir arnold.pdf] Text
Bab 4 proyek akhir arnold.pdf
Restricted to Registered users only

Download (1MB)
[thumbnail of Bab 5.pdf] Text
Bab 5.pdf
Restricted to Registered users only

Download (38kB)
[thumbnail of DAFTAR PUSTAKA.pdf] Text
DAFTAR PUSTAKA.pdf

Download (123kB)

Abstract

Dalam pengoperasian tenaga listrik terdapat sumber tenaga untuk kontrol di dalam Gardu Induk, ialah sumber arus searah (DC). Sumber tenaga untuk kontrol selalu harus mempunyai keandalan dan stabilitas yang tinggi, karena persyaratan inilah dipakai baterai sebagai sumber arus searah. Sistem DC pada Gardu Induk disuplai oleh rectifier dan baterai yang mana keduanya dihubungkan paralel dengan beban. Dalam keadaan normal Sistem DC akan disuplai oleh rectifier secara langsung, namun pada saat terjadi gangguan maka baterai akan bekerja secara otomatis mensuplai beban dengan jarak waktu tertentu. Penyebab terjadinya gangguan pada MCB lost kontak disebabkan oleh pegas/per lepas di MCB sehingga tidak dapat trip. Untuk menghidupkan lampu alarm maka dilakukan penambahan relay untuk mencegah MCB lost kontak sehingga dengan terpantaunya suplai 110 VDC pada MCB di kubikel 20 KV DA-4 maka tidak ada lagi muncul alarm sebab pengamanan sudah handal, hal ini akan meningkatkan kesiapan kerja relai di kubikel 20 KV dan meningkatkan kepekaan dalam melaksanakan pengawasan gardu induk. Untuk menjaga agar peralatan seperti rele proteksi, motor penggerak PMT dan PMS serta perlatan telekomunikasi tetap berfungsi, maka baterai harus mampu untuk menyuplai daya ke peralatan tersebut meski dalam keadaan tanpa charger maupun dalam keadaan blackout. Sehingga baterai mempunyai peranan ynag sangat penting dalam sistem tenaga listrik.

In operation electricity energy source in substation, is direct current source. Source energy for control always have reliability and high stability, Because this requiment used as direct current source. System direct current for substation supplied to rectifier and battery was two parallel connector with load in normal system direct current will supplied directly, however interference so battery will work automatic. Supplied load with certain time close. The cause of the occurrence of interference in the MCB lost contact caused by spring / per loose in the MCB so it can not trip, to turn on the alarm light is done addition of the relay to prevent MCB lost contact so with the monitored 110 VDC supply at MCB in cubicles 20 KV DA-4 then There is no more alarms arise because the security is reliable so as to Increase the readiness of work Relai at cubicles 20 KV and increase sensitivity in carrying out substations monitoring. To protect the tool protection relay, PMT motorcycle movers and PMS and tool communication still fuction, so battery must able for supplied power tools even in condtion without changer as well in condition blackout. So battery have role very important in system electricity energy.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: System direct current 110, MCB, Relay, Control Room Sistem DC 110, MCB, Relay, Ruang Kontrol
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro