PERBANDINGAN TEGANGAN TEMBUS YANG TERJADI PADA MINYAK TRANSFORMATOR BERDASARKAN USIA MINYAK

WARDANI, INTAN MUSTIKA INDAH and Erlina, Erlina (2017) PERBANDINGAN TEGANGAN TEMBUS YANG TERJADI PADA MINYAK TRANSFORMATOR BERDASARKAN USIA MINYAK. Diploma thesis, ITPLN.

[thumbnail of A. Cover PA.pdf] Text
A. Cover PA.pdf

Download (167kB)
[thumbnail of B2. LEMBAR PENGESAHAN PEMBIMBING.pdf] Text
B2. LEMBAR PENGESAHAN PEMBIMBING.pdf

Download (177kB)
[thumbnail of B1. Pengesahan, Daftar Isi.pdf] Text
B1. Pengesahan, Daftar Isi.pdf

Download (240kB)
[thumbnail of C1. BAB I.pdf] Text
C1. BAB I.pdf

Download (146kB)
[thumbnail of C2. BAB II.pdf] Text
C2. BAB II.pdf

Download (355kB)
[thumbnail of C3. BAB III.pdf] Text
C3. BAB III.pdf
Restricted to Registered users only

Download (367kB)
[thumbnail of C4. BAB IV.pdf] Text
C4. BAB IV.pdf
Restricted to Registered users only

Download (160kB)
[thumbnail of C5. BAB V.pdf] Text
C5. BAB V.pdf
Restricted to Registered users only

Download (140kB)
[thumbnail of C6. DAFTAR PUSTAKA.pdf] Text
C6. DAFTAR PUSTAKA.pdf

Download (9kB)

Abstract

Tegangan tembus merupakan indikator penting dalam menentukan kualitas isolasi suatu isolator, termasuk isolasi cair. Nilai tegangan tembus pada isolasi cair berbeda-beda tergantung pada jenis minyak yang digunakan. Beberapa faktor memengaruhi penurunan nilai tegangan tembus dan kualitas isolasi cair, salah satunya adalah umur minyak transformator. Umur minyak transformator dihitung berdasarkan lamanya minyak tersebut digunakan di dalam transformator. Seiring waktu pemakaian, kemurnian minyak dapat terkontaminasi oleh zat-zat lain yang bercampur di dalamnya, sehingga minyak menjadi tidak murni dan mengalami degradasi kekuatan dielektrik. Hal ini pada akhirnya akan menurunkan kemampuan isolasi dan meningkatkan risiko kegagalan isolasi. Berdasarkan standar IEC 60156-95, nilai tegangan tembus minyak transformator dalam kondisi baik adalah minimal 80 kV/cm, sedangkan hasil pengujian pada minyak yang telah terpakai umumnya menunjukkan nilai kurang dari 80 kV/cm. Oleh karena itu, pengujian pengaruh umur minyak transformator terhadap tegangan tembus perlu dilakukan untuk mengetahui tingkat degradasi sebagai salah satu indikator kualitas isolasi cair pada transformator.

Breakdown voltage is an important indicator in determining the quality of an insulator, including liquid insulation. The breakdown voltage value of liquid insulation varies depending on the type of oil used. Several factors influence the decrease in breakdown voltage and insulation quality, one of which is the age of transformer oil. The age of transformer oil is determined based on the duration of its use in the transformer. Over time, the purity of the oil may be contaminated by other substances mixed within it, causing the oil to become impure and leading to degradation of its dielectric strength. This degradation ultimately reduces insulation performance and increases the risk of insulation failure. According to IEC 60156-95 standards, the minimum breakdown voltage of transformer oil in good condition is 80 kV/cm, while testing results of used oil generally show values below 80 kV/cm. Therefore, testing the effect of transformer oil age on breakdown voltage is necessary to determine the level of degradation as one indicator of the quality of liquid insulation in transformers.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Minyak transformator, Tegangan tembus, Umur minyak Transformer oil, Breakdown voltage, Oil age
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 24 Feb 2026 01:56
Last Modified: 24 Feb 2026 01:56
URI: https://repository.itpln.ac.id/id/eprint/5202