DESWITA, RAHMI and Mangapul, Juara (2017) PENGUJIAN NO LOAD LOSSES DAN LOAD LOSSES TRANSFORMATOR DISTRIBUSI PADA LABORATORIUM HUBUNG SINGKAT PT.PLN (PERSERO) PUSLITBANG KETENAGALISTRIKAN. Diploma thesis, ITPLN.
Proyek Akhir 201471038.pdf
Restricted to Registered users only
Download (3MB)
Abstract
Transformator merupakan suatu peralatan yang dapat mengubah tenaga listrik dari suatu level tegangan ke level tegangan lainnya. Trafo ini tentunya diharapkan dapat bekerja pada performa yang diinginkan. Oleh karena itu, sebelum trafo dapat digunakan pada sistem tenaga listrik, maka perlu dilakukan beberapa rangkaian pengujian pada trafo daya tersebut. Pengujian transformator dilaksanakan menurut SPLN D3.002-1: 2007 (Rev. SPLN 50: 1997 dan SPLN 50: 1982) dengan melalui beberapa pengujian yang diuraikan pada IEC 60076 yaitu : pengujian rutin,pengujian jenis,pengujian khusus,pengujian serah terima. Salah satu pengujian rutin yang diuji yaitu no load losses dan load losses yang di maksudkan untuk mengetahui rugi-rugi pada inti besi dan belitan transformator tersebut. Hasil pengujian dari trafo yang diuji adalah baik karna memiliki nilai rugi-rugi pada inti besi tahanan belitan diatas batas standard uji menurut SPLN D3.002-1 : 2007 yaitu untuk pengujian no load losses 213,78 watt standardnya 210 watt toleransi nya +10 % dan untuk pengujian load losses 1439.478 watt standardnya 1420 watt toleransinya+10%,( SPLN D3.002-1 : 2007 halaman 7 )
The transformer is a device that can convert power from one voltage level to another voltage level. The transformer is certainly expected to work on the desired performance. Therefore, before the transformer can be used in the electric power system, it is necessary to do some testing on the circuit of the power transformer. Transformer testing conducted by SPLN D3.002-1: 2007 (Rev. SPLN 50: 1997 and SPLN 50: 1982) through several tests described in IEC 60076 are: routine testing, type testing, specialized testing, acceptance testing. One of the routine test is no load losses and load losses, the no load losses and load losses test is intended to losses on the transformer coil. The test result of the transformer being tested is good because it has a loss value of iron core and winding resistance above the test standard limit accordingly SPLN D3.002-1 : 2007 Ie for no load losses test 213,78 watt standard 210 watt Its tolerance +10 % and load losses test 1439.478 watt standard 1240 watt its tolerance +10 % ,( SPLN D3.002-1 : 2007 page 7 )
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | transformer,no load losses and load losses test transformator,pengujian no load losses dan load losses |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 24 Feb 2026 02:08 |
| Last Modified: | 24 Feb 2026 02:08 |
| URI: | https://repository.itpln.ac.id/id/eprint/5205 |