RIZKI, MUHAMMAD and Hariyati, Rinna and Qosim, Muchamad Nur (2020) PENGUJIAN MINYAK TRAFO DI PT.PLN GARDU INDUK (MUARA KARANG LAMA). Diploma thesis, ITPLN.
tidak bisa Proyek Akhir M. Rizki (201471040).pdf
Restricted to Registered users only
Download (15MB)
Abstract
Minyak transformator merupakan salah satu bahan isolasi cair yang berfungsi sebagai isolasi sekaligus pendingin pada transformator. Sebagai bahan isolasi, minyak transformator harus mampu menahan tegangan tinggi (stress tegangan) agar tidak terjadi tegangan tembus (breakdown). Sebagai media pendingin, minyak transformator juga harus mampu meredam panas akibat gangguan maupun saat transformator dalam kondisi berbeban. Nilai tegangan tembus yang rendah menyebabkan kekuatan dielektrik minyak menurun. Salah satu faktor utama yang memengaruhi rendahnya tegangan tembus adalah kandungan air dalam minyak transformator. Untuk menjaga keandalan minyak transformator, diperlukan pengujian kondisi minyak melalui uji tegangan tembus dan pengukuran kandungan air agar sesuai dengan standar SPLN 49-1:1982, yaitu tegangan ≥ 170 kV dan kandungan air ≤ 30 mg/kg. Pada penelitian ini digunakan metode kuantitatif. Berdasarkan hasil pengukuran di Gardu Distribusi WRG, kondisi minyak transformator dinyatakan kurang baik karena nilai tegangan tembus dan kandungan air tidak memenuhi standar, yaitu sebesar 15,5 kV/2,5 mm dan 52,96 mg/kg.
Transformer oil is one of the liquid insulation materials that functions both as insulation and as a coolant in transformers. As an insulating material, transformer oil must be able to withstand high voltage (voltage stress) to prevent breakdown. As a cooling medium, transformer oil must also be capable of dissipating heat caused by disturbances and loading conditions. Low breakdown voltage reduces the dielectric strength of the oil. One of the main factors affecting low breakdown voltage is the water content in transformer oil. To maintain transformer oil reliability, it is necessary to control its condition by conducting breakdown voltage testing and measuring water content in accordance with the SPLN 49-1:1982 standard, namely voltage ≥ 170 kV and water content ≤ 30 mg/kg. This study applies a quantitative method. Based on measurement results at the WRG Distribution Substation, the transformer oil condition is categorized as poor because the breakdown voltage and water content values do not meet the required standards, with results of 15.5 kV/2.5 mm and 52.96 mg/kg.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Minyak transformator, Tegangan tembus, Kandungan air, SPLN 49-1:1982 Transformer oil, Breakdown voltage, Water content, SPLN 49-1:1982 |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 24 Feb 2026 02:21 |
| Last Modified: | 24 Feb 2026 02:21 |
| URI: | https://repository.itpln.ac.id/id/eprint/5208 |