PENGARUH KEJENUHAN TRAFO ARUS PADA PENYULANG MELATI GARDU INDUK ANGKE

PERDANA, PUTRA and Ispranyoto, Edy (2017) PENGARUH KEJENUHAN TRAFO ARUS PADA PENYULANG MELATI GARDU INDUK ANGKE. Diploma thesis, ITPLN.

[thumbnail of COVER TA.pdf] Text
COVER TA.pdf

Download (27kB)
[thumbnail of Bagian awal (i-vii).pdf] Text
Bagian awal (i-vii).pdf

Download (97kB)
[thumbnail of BAB I TA.pdf] Text
BAB I TA.pdf

Download (76kB)
[thumbnail of BAB II TA.pdf] Text
BAB II TA.pdf

Download (263kB)
[thumbnail of BAB III TA.pdf] Text
BAB III TA.pdf
Restricted to Registered users only

Download (86kB)
[thumbnail of BAB IV & BAB V.pdf] Text
BAB IV & BAB V.pdf
Restricted to Registered users only

Download (499kB)

Abstract

Sistem distribusi tenaga listrik merupakan sistem distribusi yang berguna untuk menyalurkan tenaga listrik dari sumber daya listrik besar sampai ke konsumen. Sistem proteksi tenaga listrik yang baik harus aman, andal, dan ekonomis. Sistem proteksi pada saluran distribusi tenaga listrik merupakan suatu sistem yang terdiri dari beberapa peralatan yang berfungsi untuk mengamankan sistem distribusi dari gangguan. Gangguan pada sistem distribusi pada umumnya merupakan gangguan hubung singkat antar fasa, tiga fasa, dua fasa dan satu fasa ketanah. Tugas Akhir ini membahas pengaruh kejenuhan trafo arus sebagai pengaman Tengangan Menengah serta menentukan, arus gangguan hubung singkat dan kejenuhan trafo arus

Electricity distribution system is a useful distribution system for distributing electric power from large power source to consumer. A good electrical protection system should be safe, reliable, and economical. The protection system of the power distribution channel is a system consisting of several equipment that serves to secure the distribution system from interference. Disturbance in the distribution system is generally a short circuit between phase, three phase, two phase and one phase of the ground. This Final Project discusses the influence of saturation of the transformer as a safety of Medium Determination and Determines, Short Circuit Flow Flow and Saturation of the Current Transformer.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Protection system, Over Curren Relay, Current Transformator Sistem Proteksi, Relai Arus Lebih, Trafo Arus (CT)