Dalam Pemenuhan kebutuhan tenaga listrik terjadi pembagian beban yang pada awalnya merata tetapi karena ketidakserempakan waktu penyalaan beban-beban tersebut maka, menimbulkan ketidakseimbangan beban yang berdampak pada penyediaan tenaga listrik. Selain ketidakserempakan pemakaian beban, pengoneksian yang tidak seimbang pada fasa R, S dan T juga merupakan faktor lain yang mempengaruhi. Ketidakseimbangan beban adalah hal yang menimbulkan losses secara teknis yang akan merugikan PLN. Losses disebabkan oleh arus netral. Semakin besar arus netral pada waktu siang hari yaitu IN = 261 A, dan PN = 0,476 kW serta pada waktu malam hari IN = 280 A, dan PN = 0,548 kW pada penghantar netral transformator. Agar tercapai penyuplaian listrik yang stabil dan kontinuitas kepada konsumen maka, hal tersebut harus dapat diatasi.

In order to fulfill electrics power need there is a divided load that in the first time is carrying the same load but because not at the same time of activating the power that carrying the loads so, it will make imbalance load that affect to electrics resources, a connection that imbalance on fase R, S and T also is a factor that impact that imbalance. Imbalance of load is a factor that make losses technically which make “PLN” lossy in many sector. Losses happen because a neutral flow. A bigger/higher neutral flow at daylight is IN = 261 A, and PN = 0,476 kW also at night IN = 280 A, dan PN = 0,548 kW on neutral transformator carrier. So to make a stable and continues to consumen so, that problem must be solved.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Imbalance Network, Losses, Neutral Flow Ketidakseimbangan Beban, Losses, Arus Netral
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 24 Feb 2026 03:12
Last Modified: 24 Feb 2026 03:12
URI: https://repository.itpln.ac.id/id/eprint/5214

Actions (login required)

View Item
View Item