UPAYA MENGURANGI RUGI – RUGI DAYA PADA JARINGAN TEGANGAN RENDAH DENGAN METODE PECAH BEBAN DAN PENGGANTIAN PENGHANTAR DI GARDU SP120 PT.PLN (PERSERO) AREA KEBON JERUK

HARDIANSYAH, ARI and Mangapul, Juara (2017) UPAYA MENGURANGI RUGI – RUGI DAYA PADA JARINGAN TEGANGAN RENDAH DENGAN METODE PECAH BEBAN DAN PENGGANTIAN PENGHANTAR DI GARDU SP120 PT.PLN (PERSERO) AREA KEBON JERUK. Diploma thesis, ITPLN.

[thumbnail of PA ARI HARDIANSYAH.pdf] Text
PA ARI HARDIANSYAH.pdf
Restricted to Registered users only

Download (3MB)

Abstract

Rugi – rugi daya pada Gardu SP120 disebabkan oleh karena salah satu fasanya melebihi KHA, beban yang tidak seimbang dan penampang penghantar yang kecil. Salah satu cara untuk mengurangi rugi daya adalah dengan metode pecah beban dan penggantian penampang penghantar JTR yang lebih besar. Setelah dilakukannya pecah beban pada jurusan B, rugi daya menurut perhitungan dan pencatatan kWh meter di lapangan, berkurang rugi dayanya dari 12.940,64 kWh / bulan menjadi 5.986,04 kWh / bulan. Dengan selisih antara sebelum dan setelah pecah beban adalah 6.954,6 kWh / bulan. Terjadi penurunan rugi daya sebesar 8,2%. Setelah dilakukannya penggantian penampang penghantar, rugi daya berkurang dari 34,15182264 kW menjadi 24,071769262 kW. Terjadi penurunan rugi daya sebesar 10,08013002 kW. Secara perhitungan kerugian daya yang didapat hasilnya tidak sama dengan kenyataan di lapangan, hal ini disebabkan karena perhitungan diatas tidak memperhitungan rugi – rugi lainnya seperti yang diakibatkan oleh pemasangan Tap Konektor yang tidak benar, pencurian listrik, rugi trafo, rugi jatuh tegangan dan faktor lainnya.

The power losses at SP120 are caused by one of the phases in exceed of KHA, unbalanced load and small conducting cross section. One way to reduce power losses is by breaking load methods and replacing larger JTR conducting cross-sections. After a load burst in the B department, the loss of power by calculation and recording of kWh meters in the field, reduced its power loss from 12,940.64 kWh / month to 5,986.04 kWh / month. By difference between before and after burst load is 6,954,6 kWh / month. There was a loss of power loss of 8.2%. Following the replacement of the conducting cross section, the power loss is reduced from 34.15182264 kW to 24.071769262 kW. There is a loss of power loss of 10.08013002 kW. The calculation of power loss is not the same as the reality in the field, this is because the above calculation does not calculate other losses as caused by incorrect connector Tap installation, electricity theft, loss of transformer, voltage loss and other factors.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Power losses, Low Voltage Network, Conductor. Rugi – rugi daya, jaringan tegangan rendah, penghantar.
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Vokasi > D3 Teknologi Listrik
Depositing User: Sudarman
Date Deposited: 24 Feb 2026 06:34
Last Modified: 24 Feb 2026 06:34
URI: https://repository.itpln.ac.id/id/eprint/5236

Actions (login required)

View Item
View Item