UPAYA MENGATASI BEBAN LEBIH PADA GARDU DISTRIBUSI T24A DENGAN METODE PECAH BEBAN DI PT. PLN (PERSERO) AREA MENTENG

NURROJABBINARA, SOLEH and Ispranyoto, Edy (2017) UPAYA MENGATASI BEBAN LEBIH PADA GARDU DISTRIBUSI T24A DENGAN METODE PECAH BEBAN DI PT. PLN (PERSERO) AREA MENTENG. Diploma thesis, ITPLN.

[thumbnail of Cover.pdf] Text
Cover.pdf

Download (104kB)
[thumbnail of lembar pengesahan, dll.pdf] Text
lembar pengesahan, dll.pdf

Download (1MB)
[thumbnail of Abstrak ina.pdf] Text
Abstrak ina.pdf

Download (7kB)
[thumbnail of Abstrak eng.pdf] Text
Abstrak eng.pdf

Download (6kB)
[thumbnail of BAB I,II,III.pdf] Text
BAB I,II,III.pdf
Restricted to Registered users only

Download (837kB)
[thumbnail of Bab IV,V.pdf] Text
Bab IV,V.pdf
Restricted to Registered users only

Download (678kB)
[thumbnail of daftar pustaka.pdf] Text
daftar pustaka.pdf

Download (243kB)

Abstract

Kemajuan teknologi dan sangat pentingnya peranan tenaga listrik untuk memenuhi kebutuhan pelanggan, menuntut Perusahaan Listrik Negara (PLN) selalu berusaha meningkatkan mutu dan keandalan dalam pendistribusian energy listrik ke pelanggan yang dituangkan dalam bentuk road map penurunan gangguan trafo dari tahun ke tahun guna menuju perusahaan dengan pelayanan kelas dunia. Trafo merupakan peralatan listrik yang sangat penting karena berhubungan langsung dengan saluran transmisi dan distribusi listrik. Gangguan pada trafo dapat menyebabkan rusaknya dan menurunnya kinerja dari trafo. Contoh penyebab dari rusaknya trafo adalah overload dan beban tidak seimbang. Overload terjadi karena beban yang terpasang pada trafo melebihi kapasitas maksimum dari trafo dimana arus beban melebihi arus beban nominal pada trafo tersebut. Oleh karena itu diperlukan upaya perbaikan dengan menurunkan jumlah trafo overload yang merupakan salah satu inisiatif perbaikan yang didapatkan dengan melakukan pekerjaan pecah beban. Setelah adanya kegiatan pecah beban, beban fasa dan beban total trafo mengalami penurunan pada setiap fasanya dari 995.004 VA menjadi 620.216 VA dan persentase total pada trafo mengalami penurunan dari 99.5% menjadi 62.02% sehingga trafo dapat dikatakan normal dan dapat bekerja secara optimal.

Advances in technology and the very important role of el;ectricity to meet the needs of customers, demanding State Electricity Company (PLN) is always trying to improve the quality and reliability in the distribution of electrical energy to customers as outlined in the form of road map decline disruption transformer from year to year in order to lead the company with services world class. The transformer is an electrical equipment which is very important because it relates directly to the electricity transmission and distribution channels. Disturbances in the transformer can cause damage and decrease the performance of the transformer. Examples of the cause of damage to the transformer is overloaded and unbalanced load. Overload occurs because the load that is attached to the transformer exceeds the maximum capacity of the transformer where the load current exceeds the nominal load current in the transformer. Therefore, it required improvement by reducing the number of transformer overload which is one of the initiatives that is obtained by performing repair work load rupture. After the events broke out load, load transformer phase and total load decreased in every phase of 995.004 620.216 VA and VA into the transformer total percentage decreased from 99.5% to 62.02%, so the transformer can be considered normal and can work optimally.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transformer Overload, Rupture load, Substation Distribution Trafo Overload, Pecah beban, Gardu Distribusi