Transformator distribusi merupakan salah satu komponen utama pada suatu sistem pendistribusian tenaga listrik ke pelanggan. Kerusakan pada Transformator Distribusi menyebabkan kontiniutas pelayanan terhadap konsumen akan terganggu. Agar dapat berfungsi dengan baik, maka trafo harus dipelihara dengan baik menggunakan sistem pemeliharaan dan peralatan yang tepat. Pemeliharaan tranformator distribusi 20kV di PT. PLN Area Cikokol dilakukan 4 pengukuran yaitu tahanan isolasi, perbandingan belitan, tegangan tembus minyak, dan tahanan belitan. Dari data hasil pengukuran yang dilakukan, tahanan isolasi pada trafo masih cukup baik karena masih diatas standar minimum tahanan isolasi yaitu 637 M, hasil pengukuran belitan trafo antara sisi primer (TM) dengan sisi sekunder (TR) dari tap 1 sampai dengan tap 5 dinyatakan baik karena masih sesuai standar SPLN 0,5%, minyak trafo dinyatakan lulus uji tegangan tembus dengan hasil 59,88 kV/mm memenuhi persyaratan sesuai dengan standar yaitu ≥ 50kV / 2,5 mm, dan tahanan belitan trafo dalam keadaan seimbang karena hasil tes tahanan belitan (fasa R,S,T dengan netralnya) hasilnya hampir sama. Dari data yang didapat nantinya akan dilakukan analisa dan evaluasi yang akan menentukan tindakan selanjutnya. Pengukuran ini dilakukan untuk mempertahankan kondisi dan meyakinkan bahwa transformator tersebut dapat berfungsi sebagai mestinya, sehingga dapat mempertahankan reliability, avability dan efficiency sistem secara keseluruhan.
Transformer distribution is one of the main components in a system of distribution of electricity to customers. Damage to the Transformer Distribution causes the continuity of service to consumers will be disrupted. In order to function properly, the transformer must be maintained properly using proper maintenance and equipment systems. Maintenance of 20kV distribution transformer at PT. PLN Area Cikokol carried out 4 measurements namely isolation resistance, comparison windings, voltage through oil, and resistance winding. From the measurement data conducted, the isolation resistance on the transformer is still quite good because it is still above the minimum standard of isolation resistance that is 637 M, the transformer winding measurement results between the primary side (TM) with the secondary side (TR) from tap 1 to tap 5 is stated either because it is still in accordance with the standard SPLN 0.5%, transformer oil passed the test voltage penetration with the results of 59.88 kV / mm meet the requirements in accordance with the standard that is ≥ 50kV / 2.5 mm, and the winding resistance of the transformer in a balanced state because the results test of entanglement resistance (phase R, S, T with neutral) the result is almost the same. From the data obtained will be done analysis and evaluation that will determine the next action. This measurement is carried out to maintain the condition and ensure that the transformer can function properly, so as to maintain overall reliability, avability and efficiency of the system.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Transformer, distribution, 20kV, maintenance Transformator, distribusi, 20kV, pemeliharaan. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 25 Feb 2026 06:27 |
| Last Modified: | 25 Feb 2026 06:27 |
| URI: | https://repository.itpln.ac.id/id/eprint/5264 |