SYAHIDIN, AMAR and Hariyati, Rinna (2016) MODIFIKASI SISTEM KONTROL SEALING UNTUK EFISIENSI MAIN COOLING WATER PUMP PADA WATER INTAKE BLOK 1-2 DI UPJP PRIOK. Diploma thesis, ITPLN.
1. Cover.pdf
Download (233kB)
2. Lembar pengesahan.pdf
Download (235kB)
7. Abstrak indonesia.pdf
Download (233kB)
8. Abstrak bhs inggris.pdf
Download (234kB)
13. BAB I.pdf
Download (24kB)
14. BAB II.pdf
Download (313kB)
15. BAB III.pdf
Restricted to Registered users only
Download (789kB)
16. BAB IV.pdf
Restricted to Registered users only
Download (544kB)
17. BAB V.pdf
Restricted to Registered users only
Download (157kB)
18. Daftar Pustaka&Riwayat Hidup.pdf
Restricted to Registered users only
Download (194kB)
Abstract
Water intake plant merupakan salah satu dari Balance Of Plant (BOP) yang berfungsi sebagai penyuplai air laut, untuk kebutuhan pembuatan air tawar pada desalination plant dan juga sebagai penyuplai air laut untuk sistem pendinginan pada condenser dan Close Cooling Water (CCW) yang dipompakan oleh Main Cooling Water Pump (MCWP). Namun pada MCWP dibutuhkan air untuk sealing dan pendinginan pelumas pada bearing motor MCWP. Untuk saat ini sistem sealing pada MCWP disuplai dari service water pada saat MCWP akan beroperasi. Namun setelah MCWP beroperasi maka sistem sealing menggunakan air laut yang disuplai dari booster pump. Tujuan dari penelitian ini yaitu untuk mengurangi penggunaan service water sebagai sealing dan cooling pelumas pada MCWP dan juga menghemat pemakaian daya sendiri, serta menjaga efisiensi dari MCWP. Dengan memodifikasi sistem control sealing atau merubah squence dari MCWP dan menambah jalur pemipaan dari Screen Wash Pump (SWP) menuju MCWP. Sehingga kebutuhan air untuk sealing dan cooling pelumas bearing diambil dari discharge SWP yang diatur pembukaannya dengan mengontrol selenoid valve.
Water intake plant is one of the Balance Of Plant (BOP), which serves as a supplier of sea water, for manufacturing of fresh water desalination plant as well as a supplier of seawater for the cooling system at the condenser and Close Cooling Water (CCW) which is pumped by Main cooling Water Pump (MCWP). But in MCWP need water for sealing and cooling lubricants in the motor bearings MCWP. For now at MCWP sealing system is supplied from water service when MCWP will operate. But after the operation, the sealing system using sea water supplied from the booster pump. The purpose of this research is to reduce the use of water service as sealing and cooling lubricants in MCWP and also saves power consumption itself, as well as maintaining the efficiency of MCWP. By modifying the control system of sealing or change squence of MCWP and adds to the pipe lines of Screen Wash Pump (SWP) to MCWP. So the need for cooling water for sealing and bearing lubricants taken from the discharge SWP regulated by controlling the solenoid valve opening.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | Main Cooling Water Pump (MCWP), Sealing Control System Modifications, Selenoid Valve. Main Cooling Water Pump (MCWP), Modifikasi Sistem Kontrol Sealing, Selenoid Valve. |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Vokasi > D3 Teknologi Listrik |
| Depositing User: | Sudarman |
| Date Deposited: | 25 Feb 2026 09:31 |
| Last Modified: | 25 Feb 2026 09:31 |
| URI: | https://repository.itpln.ac.id/id/eprint/5278 |