KURNIANTO, SANDI and NURHASANAH, ROSWATI (2021) PENGARUH TEKANAN VAKUM KONDENSOR TERHADAP HEAT RATE TURBIN PADA TEMPERATURE AIR PENDINGIN 28˚C DAN 30˚C DI UNIT 1 PLTU 3 BENGKAYANG. Diploma thesis, ITPLN.
![[thumbnail of 10.6_Sandi Kurnianto_201712036_Skripsi.pdf]](https://repository.itpln.ac.id/style/images/fileicons/text.png)
10.6_Sandi Kurnianto_201712036_Skripsi.pdf
Restricted to Repository staff only
Download (3MB)
Abstract
Kondensor merupakan alat penukar kalor atau biasa disebut dengan heat
exchanger yang berfungsi untuk mengondensasi uap kerja keluaran dari Turbine
menjadi air. Kevakuman kondensor selalu dijaga nilainya karena perubahan nilai
kevakuman kondensor dapat berpengaruh pada nilai efisiensi turbin uap. Permasalahan
yang ada pada PLTU 3 Bengkayang ini disebabkan beberapa fraktor yaitu disebabkan
oleh tinggi beban dan didalam tube condenser atau kotornya pipa - pipa kondensor yang
ditunjukkan dengan turunnya nilai tekanan vakum, hingga menyebabkan nilai
kevakuman kondensor mendekati tekanan atmosfir dan mengakibatkan peningkatan
heat rate turbin uap bahkan hingga menyebabkan unit pembangkit trip (mati mendadak).
Penelitian ini bertujuan untuk mengetahui pengaruh perubahan tekanan vakum terhadap
Heat rate pada turbin uap. Heat rate turbin dapat dilihat dari energi panas yang
dimasukkan untuk menghasilkan listrik sebesar 1 kwh.. Hasil analisis yang didapatkan
yaitu kurva perbandingan tekanan vakum pada temperatur suhu air pendingin kondensor
28˚C dan 30˚C perhitungan nilai Heat Rate didapatkan hasil pada suhu air 28 ˚C setiap
penuruanan tekanan sebesar 1 kPa maka terjadi penurunan heat rate sebesar 42,7
kcal/kWh dan pada suhu air pendingin 30 ˚C setiap penurunan tekanan sebesar 1 kPa
heat ratenya turun sebesar 46,25 kcal.kWh.
The condenser is a heat exchanger or commonly referred to as a heat exchanger
which functions to condense the working steam output from the turbine into water. The
condenser vacuum value is always maintained because changes in the condenser
vacuum value can affect the efficiency of the steam turbine. The problems that exist in
PLTU 3 Bengkayang are caused by several factors, namely caused by high loads and
inside the condenser tube or dirty condenser pipes as indicated by a decrease in the
vacuum pressure value, causing the condenser vacuum value to approach atmospheric
pressure and result in an increase in the steam turbine heat rate even causing the
generating unit to trip (sudden shutdown). This study aims to determine the effect of
changes in vacuum pressure on the heat rate of the steam turbine. The turbine heat rate
can be seen from the heat energy entered to produce 1 kwh of electricity. The results of
the analysis obtained are the vacuum pressure comparison curve at the condenser
cooling water temperature of 28˚C and 30˚C. Calculation of the Heat Rate value is
obtained at a water temperature of 28C. C for every 1 kPa decrease in pressure, there
will be a decrease in heat rate of 42.7 kcal/kWh and at a temperature of 30 C of cooling
water for every 1 kPa decrease in pressure, the heat rate will decrease by 46.25
kcal/kWh
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | Tekanan Vakum Kondenser, Heat Rate Turbine. Condenser Vacuum Pressure, Turbine Heat Rate |
Subjects: | Skripsi Bidang Keilmuan > Teknik Mesin |
Divisions: | Fakultas Teknologi dan Bisnis Energi > S1 Teknik Mesin |
Depositing User: | Nurul Hidayati |
Date Deposited: | 04 Sep 2025 19:36 |
Last Modified: | 04 Sep 2025 19:36 |
URI: | https://repository.itpln.ac.id/id/eprint/569 |