LISTIYANTO, ATHUR and SUMANI, SAMBODHO (2015) RANCANG BANGUN PENYULANG 20 KV. Diploma thesis, ITPLN.
1.1.halaman judul.pdf
Download (19kB)
1.2.pengesahan new.pdf
Download (60kB)
1.8.abstrak Indonesia.pdf
Download (139kB)
1.9.abstrak bahasa Ingris.pdf
Download (139kB)
2.1. BAB1.pdf
Download (89kB)
2.2.BAB2.pdf
Download (496kB)
2.3.BAB3.pdf
Restricted to Registered users only
Download (462kB)
2.4.BAB 4.pdf
Restricted to Registered users only
Download (675kB)
2.5.BAB5.pdf
Restricted to Registered users only
Download (83kB)
3.1.daftar pustaka.pdf
Download (5kB)
Abstract
Penyulang harus diproteksi untuk membatasi arus lebih dan hubung singkat, untuk protek tersebut digunakan Relay arus lebih. Relay arus lebih mempunyai 2 elemen, elemen thermal dan elemen elektromagnetik. Apabila terjadi hubung singkat maka di lokasi akan terjadi bunga api yang sangat besar shingga akan terjadi kebakaran pada lokasi hubung singkat. Karena itu hubung singkat harus dihentikan secepat mungkin menggunakan relay arus lebih yang dapat bekerja dengan cepat karena adanya elemen elektromagnetik. Disamping arus lebih dan hubung singkat antar phasa, bahaya juga bisa muncul apabila terjadi gangguan phasa tanah. Dalam membatasi arus hubung singkat phasa tanah digunakan tahanan yang menghubungkan titik netral transformator dengan tanah. Apabila tahanan ini terlalu besar maka pada gangguan phasa- tanah bisa menimbulkan sympathetic trip. Apabila tahanan tersebut dapat membatasi arus hubung singkat, agar tidak melebihi arus nominal tranformator gardu induk maka besar arus gangguan phasa-tanah tidak merusak Transformator gardu induk. Sehingga kita hanya memperhatikan kerusakan-kerusakan yang tibul pada lokasi gangguan. Dalam skripsi ini arus hubung singkat 1 phasa – tanah dibatasi sama dengan arus nominal transformator. Transformator gardu induk yang digunakan adalah 60 MVA. Mengingat bahwa arus gangguan hubung singkat phasa-phasa sangat besar perlu dilakukan langka- langka untuk mengusahakan sekecil mungkin gangguan phasa-phasa tersebut. Pada sistem SUTM dimana sering terjadi gangguan, dimungkinkan sistem penutup balik. Sistem penutup balik sebaiknya hanya aktif pada gangguan phasa-tanah.
Transmission line must be protected in order to limit over current and short circuit,to protect it using over current relay.Over current relay have 2 elements,thermal and electromagnetic elements.If happen short circuit in this location so will make the most arcing then will cause burning at location of short circuit.Therefore short circuit must be stopped as fast as using over current relay that can work rapidly because of electromagnetic element.Beside of over current and short circuit phase to phase,dangerous also can happen is ground fault.To limit short circuit current of phase to ground is used resistance that related to neutral point of transformator to ground.If value of this resistance is too large so ground fault can make sympathetic trip.if that resistance can limit short circuit current which it over the nominal current of transformator of house station so value of current of phase to ground fault can’t damage transformator of house station.So we just attention destructions which happen in location of fault.In this mini thesis, short circuit current of phase to ground is limited same with nominal current of transformator.Transformator that used in house station is 60 MVA.To remind that short circuit current of phase to ground is too large so need more steps to make phase to phase fault as small.In this SUTM system which is often happen fault,using recloser.Recloser should be active.
| Item Type: | Thesis (Diploma) |
|---|---|
| Uncontrolled Keywords: | penyulang 20 kv,Gangguan pada penyulang 20 kv. Transmission line 20 kV, protection systems |
| Subjects: | Skripsi Bidang Keilmuan > Teknik Elektro |
| Divisions: | Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro |
| Depositing User: | Sudarman |
| Date Deposited: | 06 Mar 2026 09:01 |
| Last Modified: | 06 Mar 2026 09:01 |
| URI: | https://repository.itpln.ac.id/id/eprint/5848 |