PENUTUP BALIK DAN SINKRONISASI PADA TEGANGAN 150 kV

APRIYADI, IRCHAM and SUMANI, SAMBODHO (2015) PENUTUP BALIK DAN SINKRONISASI PADA TEGANGAN 150 kV. Diploma thesis, ITPLN.

[thumbnail of SKRIPSI IRCHAM.pdf] Text
SKRIPSI IRCHAM.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Pada sistem interkoneksi 150 kV seperti pada sistem Jawa-Bali akan cukup banyak gangguan sambaran petir, sebagian besar sambaran petir merupakan gangguan yang bersifat sementara (temporer). Sehingga apabila pemutus sudah terbuka maka arus hubung singkat hilang. Pemutus secara otomatis bisa ditutup kembali, hanya saja waktu ditutup kembali dijamin kondisi masih sinkron. Pada umumnya transmisi 150 kV Jawa-Bali terdiri dari sirkit ganda dan gangguan terjadi hanya pada saluran satu saja sehingga saluran yang terganggu terbuka, sistem masih sinkron. Salah satu metoda pengurangan interupsi aliran daya (suplai energy) yang diakibatkan gangguan pada sistem transmisi. Terutama untuk gangguan yang bersifat sementara (temporer) dapat dilakukan dengan menggunakan penutup balik tiga fasa atau satu fasa, jika terjadi gangguan pada transmisi kedua PMT pada ujung saluran maka serempak membuka dan setelah gangguan dibebaskan PMT akan menutup kembali sehingga aliran daya akan kembali seperti semula.

At 150 kV interconnection system as the Java-Bali system would much short lightning strike. lightning strike largely a temporary interruption so that when the breakeris open, the short circuit current is lost. Breaker automatically be closed again, it's just a closed back guaranteed condition still in sync. In general,150 kV transmission Java-Bali consists of a double circuit and interference occurs only one channel only so disturbed channel is open, the system is still in sync. One method interrupts the flow of power eduction (energy supply) which caused disturbances in the transmission system, especially for disorders that are not settled (temporary) can be done by using the recloser three-phase or single phase, I fan interruption in the transmission of the PMT at the end of the line in opening and after interruption released, PMT will closed again.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Transmission150 kV, short Disorders, recloser three phase or single phase Transmisi 150 kV, Gangguan Temporer, Penutup balik tiga fasa atau satu fasa
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 09 Mar 2026 10:01
Last Modified: 09 Mar 2026 10:01
URI: https://repository.itpln.ac.id/id/eprint/6103

Actions (login required)

View Item
View Item