Abstract
ANALISIS PENGARUH BEBAN TERHADAP EFEKTIVITAS KONDENSOR PLTU BARRU UNIT 1. Kondensor adalah salah satu jenis mesin penukar kalor (heat exchanger) yang berfungsi untuk mengkondensasikan fluida kerja. Kinerja dari suatu condenser dapat dilihat dari perhitungan efektifitasnya. Penelitian ini bertujuan menganalisis pengaruh pembebanan dan terhadap efektivitas kondensor dan faktor yang mempengaruhi efektivitas dari kondensor. Dengan hasil penelitian yang diperoleh bahwa semakin naik beban akan mempengaruhi efektivitas kondensor. Efektivitas kondensor dengan beban 24,29 MW sebesar 45.604%, pada beban 27,63 MW sebesar 34.080%, pada beban 35,65 MW sebesar 61.157%, pada beban 36,55 MW sebesar 61.856%, pada beban 37,5 MW sebesar 42.630%, dan pada beban 38,37 MW sebesar 43.730%. Indikator efektivitas kondensor dapat di lihat dari temperature outlet dari air pendingin, karena semakin tinggi temperatur outlet air pendingin maka efektivitas kondensor akan semakin tinggi, karena semakin tinggi temperature outlet air pendingin maka semakin banyak energy panas yang di serap oleh kondensor untuk di olah kembali di boiler. Temperatur outlet kondensor di pengaruhi oleh temperature exhaust turbin, semakin tinggi temperature exhaust turbin maka semakin tinggi panas yang dapat di serap oleh kondensor.
ANALYSIS OF THE EFFECT OF LOAD ON THE EFFECTIVENESS OF
THE CONDENSOR OF THE NEW PLTU POWER UNIT 1. The condenser is a type of heat exchanger that functions to condense the working fluid. The performance of a condenser can be seen from the calculation of its effectiveness. This study aims to analyze the effect of loading and on the effectiveness of the condenser and the factors that affect the effectiveness of the condenser. With the research results obtained that the increase in load will affect the effectiveness of the condenser. The effectiveness of the condenser with a load of 24.29 MW is 45.604%, at a load of 27.63 MW it is 34.080%, at a load of 35.65 MW it is 61.157%, at a load of 36.55 MW it is 61.856%, at a load of 37.5 MW it is 42.630 %, and at 38.37 MW load of 43.730%. The indicator of the effectiveness of the condenser can be seen from the outlet temperature of the air cooler, because the higher the outlet temperature of the air cooler, the higher the effectiveness of the condenser, because the higher the outlet temperature of the air conditioning, the more heat energy is absorbed by the condenser to be reprocessed in the boiler. The condenser outlet temperature is influenced by the turbine exhaust temperature, the higher the turbine exhaust temperature, the higher the heat that can be absorbed by the condenser.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | condesor, turbin, PLTU |
Subjects: | Skripsi Bidang Keilmuan > Teknik Mesin |
Divisions: | Fakultas Teknologi dan Bisnis Energi > S1 Teknik Mesin |
Depositing User: | Nurul Hidayati |
Date Deposited: | 08 Sep 2025 02:40 |
Last Modified: | 08 Sep 2025 02:40 |
URI: | https://repository.itpln.ac.id/id/eprint/614 |