Pada pembangkit listrik tenaga uap di PLTU JENEPONTO yang berlokasikan di PT.
Bosowa Energi PLTU Jeneponto ditemukan sebuah komponen pada unit 1 dimana terdapat
kebocoran water wall tube Ini mengakibatkan Unit Trip atau dalam hal ini kerusakan fatal
peralatan. Pada water wall tube yang mengalami kegagalan awal mula berupa kebocoran tube
karena terdapat tube yang mengalami cacat lubang kemudian tube tersebut di rebuild dan hasil
dari rebuild tersebut kurang bagus karena masih ada celah antara tube dengan material rebuild
sehingga terjadi kegagalan pada sambungan las rebuild yang terjadi pada daerah water wall tube
yang mengakibatkan tube tidak kuat menahan temperatur dan tekanan uap yang terus menerus
dan menyebabkan pipa bocor. Faktor yang dapat menyebabkan kegagalan antara lain adalah
lingkungan dan temperatur, posisi pengelasan yang salah, elektroda yang tidak sesuai dengan
material base metal, faktor operasional dan lain sebagainya. Untuk mengatasi hal tersebut, penulis
melakukan pengujian terhadap material water wall tube dengan pengujian uji Tarik dan uji
kekerasan dimana di harapkan dari hasil pengujian tersebut dapat mengungkap kekuatan dari
material.

At the steam power plant at PLTU JENEPONTO which is located at PT. Bosowa Energi
PLTU Jeneponto found a component in unit 1 where there was a water wall tube leak. This
resulted in Unit Trip or in this case fatal equipment damage. On the water wall tube, the initial
failure was in the form of a tube leak because there was a tube with a defective hole then the tube
was rebuilt and the results of the rebuild were not good because there was still a gap between the
tube and the rebuild material, resulting in failure of the rebuild welding connection that occurred
in the water wall tube area which causes the tube to be unable to withstand continuous temperature
and steam pressure and causes the pipe to leak. Factors that can cause failure include the
environment and temperature, the wrong welding position, electrodes that are not compatible with
the base metal material, operational factors and so on. To overcome this, the authors conducted
tests on the water wall tube with tensile test and hardness test where it is expected that the test
results can reveal the strength of the material.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: uji Tarik, uji kekerasan water wall tube furnace Tensile test, water wall tube furnace hardness test