PEMASANGAN CURRENT TRANSFORMER (TRAFO ARUS) PADA KUBIKEL PELANGGAN KHUSUS DI PT.PLN AREA BANTEN UTARA

GIRSANG, CARLOS MELANDEZ and Mahari, Sukandi (2016) PEMASANGAN CURRENT TRANSFORMER (TRAFO ARUS) PADA KUBIKEL PELANGGAN KHUSUS DI PT.PLN AREA BANTEN UTARA. Diploma thesis, ITPLN.

[thumbnail of 1. Cover.pdf] Text
1. Cover.pdf

Download (100kB)
[thumbnail of 2. Lembar Awal.pdf] Text
2. Lembar Awal.pdf

Download (359kB)
[thumbnail of abstrak.pdf] Text
abstrak.pdf

Download (282kB)
[thumbnail of abstrak inggris.pdf] Text
abstrak inggris.pdf

Download (146kB)
[thumbnail of BAB I -5.pdf] Text
BAB I -5.pdf
Restricted to Registered users only

Download (1MB)

Abstract

Seiring dan berkembangnya perindustrian di Indonesia serta banyaknya permohonan penambahan daya oleh industri maka PT.PLN selaku perusahaan BUMN menyiapkan alat untuk mengukur arus agar dapat membaca daya yang relatif besar.Pada Tugas akhir ini membahas tentang Current Transformer.Current Transformer (Trafo Arus) adalah peralatan listrik yang dipergunakan dalam rangkaian arus bolak-balik,yang dapat memperkecil arus besar menjadi arus kecil fungsinya untuk memperoleh arus yang sebanding dengan arus yang hendak dipergunakan dan untuk memisahkan sirkuit dari sistem yang arusnya diukur,CT Pada umumnya dipakai pada peralatan yang nilainya besar dan juga sebagai proteksi serta isolasi sirkit sekunder dari sisi primernya. Pada tugas akhir ini akan dibahas tentang penggunaan Current Transformer sebagai alat bantu pengukuran.Proses transformasi dari arus primer menjadi arus sekunder, selalu diikuti dengan rugi-rugi disetiap bagian trafo arus. Rugi-rugi yang muncul pada trafo arus bisa berupa rugi pada kumparan primer sekunder maupun rugi-rugi yang muncul pada sisi inti Akibat adanya rugi-rugi tersebut, maka besarnya arus sekunder sebenarnya/aktual menjadi berbeda dengan nilai arus sekunder pengenal. Perbedaan antara arus sekunder sebenarnya dengan arus sekunder pengenal inilah yang biasa disebut kelas akurasi/ketelitian. Dalam hal ini penulis akan mejelaskan tentang cara pemasangan Current Transfomer dan perhitungan kesalahan arus

As the development of industry in Indonesia and the large request for addition of power by the industry as the state-owned company PT PLN preparing tools to measure the current in order to read the data is relatively largethis thesis discusses the current transformer. current transformers are electrical equipment used in a series of alternating current, which can reduce the flowbig to be small. function to obtain a current proportional to the current which was to be used and to separate sirkut from its current system measuredCT is generally used on the equipment as well as its great value and secondary circuit protection as well as isolation from the primary sideIn this final project will discuss the use of current transformers as process measurement toolsmeasurement of the transformation process of the primary current into a secondary current, is always followed by losses arising on the side of the coreas a result of these losses, the amount of secondary current in fact be different from the current value of the secondary identifiersThis is commonly called the class of accuracyin this case the author describes how to install current transformers and fault current calculations.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Current Transformer, Tingkat Ketelitian CT, dan Kesalahan Arus current transformer, level of accuracy, and fault currents
Subjects: Skripsi
Bidang Keilmuan > Teknik Elektro
Divisions: Fakultas Ketenagalistrikan dan Energi Terbarukan > S1 Teknik Elektro
Depositing User: Sudarman
Date Deposited: 13 Mar 2026 22:32
Last Modified: 13 Mar 2026 22:32
URI: https://repository.itpln.ac.id/id/eprint/6298

Actions (login required)

View Item
View Item