ANALISIS PENGARUH TEKANAN DAN SUHU FLUIDA KERJA TERHADAP KERUSAKAN MATERIAL PADA DISK GATEVALVE DRAIN TCA PADA UNIT 3 PLTGU PRIOK

NAHOR, ARI FAJAR and Prabowo, Eri (2024) ANALISIS PENGARUH TEKANAN DAN SUHU FLUIDA KERJA TERHADAP KERUSAKAN MATERIAL PADA DISK GATEVALVE DRAIN TCA PADA UNIT 3 PLTGU PRIOK. Diploma thesis, ITPLN.

[thumbnail of Tugas Akhir Ari Fajar Nahor_201812025.pdf] Text
Tugas Akhir Ari Fajar Nahor_201812025.pdf
Restricted to Repository staff only

Download (4MB)

Abstract

Disk gate valve drain tca unit 3 PLTGU Priok telah mengalami kerusakan akibat korosi pada material disk tersebut. Jenis kerusakan utama yang dialami oleh disk gate valve adalah korosi material. Korosi pada material terjadi akibat interaksi kimiawi antara fluidakerja dan material valve, terutama pada suhu dan tekanan tinggi. Tekanan yang lebih tinggi meningkatkan tegangan pada material valve, sementara suhu tinggi mempercepat reaksi korosi dan menurunkan ketahanan material. Akibatnya, kombinasi tekanan dan suhu yang melebihi batas operasi normal dapat secara drastis memperpendek umur valvedan meningkatkan frekuensi kegagalan komponen. Agar dapat menganalisa kerusakan dapat dilakukan dengan berbagai macam metode seperti pengamatan visual, pengujian metalografi, pengujian SEM-EDX, serta pengujian kekerasan vickers. Dari hasil pengujian kekerasan disk gate valve menggunakan pengujian kekerasan Vickers dengan nilai rata-rata yang dihasilkan yaitu 192 HV, jika dikonversi pada kekerasan Brinell diperoleh hasil 190 HB, dan jika dikonversi menjadi kekerasan Rockwell-b diperoleh hasil92 HRB. Serta hasil pengujian SEM-EDX pada material disk gate valve terdapat hasil elemental mapping menunjukan penyebaran kalium dan beberapa senyawa atom. Sepertiunsur yang terdeteksi dari material ini adalah C (karbon), Fe (besi), O (oksigen), N (nitrogen). Hasil mapping menunjukan penyebaran kalium dan beberapa senyawa atom lainnya. Seperti yang terlihat dari analisa EDX, elemen C (25.43), Fe (73.19), O (0.58), N (0.80)

The gate valve disk of drain tca unit 3 PLTGU Priok has been damaged due to corrosionof the disk material. The main type of damage experienced by the gate valve disk is material corrosion. Corrosion of the material occurs due to chemical interactions betweenthe working fluid and the valve material, especially at high temperatures and pressures. Higher pressures increase the stress on the valve material, while high temperatures accelerate the corrosion reaction and decrease the resistance of the material. As a result, the combination of pressure and temperature exceeding normal operating limits can drastically shorten valve life and increase the frequency of component failure. In order toanalyze the damage, it can be done by various methods such as visual observation, metallographic testing, SEM-EDX testing, and Vickers hardness testing. From the resultsof testing the hardness of the gate valve disk using Vickers hardness testing with the resulting average value of 192 HV, if converted to Brinell hardness the result is 190 HB,and if converted to Rockwell-b hardness the result is 92 HRB. As well as the results of SEM-EDX testing on disk gate valve material, there are elemental mapping results showing the distribution of potassium and several atomic compounds. Such elements detected from this material are C (carbon), Fe (iron), O (oxygen), N (nitrogen). The mapping results show the distribution of potassium and some other atomic compounds. As seen from the EDX analysis, the elements C (25.43), Fe (73), O (oxygen), and N (nitrogen) were detected.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Korosi, disk gate valve, metalografi, SEM-EDX, vickers Corrosion, disk gate valve, metallography, SEM-EDX, vicke
Subjects: Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Fakultas Teknologi dan Bisnis Energi > S1 Teknik Mesin
Depositing User: Nurul Hidayati
Date Deposited: 09 Sep 2025 08:22
Last Modified: 09 Sep 2025 08:22
URI: https://repository.itpln.ac.id/id/eprint/757

Actions (login required)

View Item
View Item