Abstract

Pembangkit Listrik Tenaga Uap UJP LONTAR PT> PLN (Persero) menyuplai 3x315 MW yang dihasilkan dari 3 unit cerobong. PLTU ini telah beroprasi sekitar 15 tahun sejak tahun 2009. Total kapasitas keempat unit ini sebesar 945MW. pembangkit listrik ini memiliki sistem pembuangan pembakaran yang digunakan untuk memindahkan gas buang sisa pembakaran di boiler ke cerobong asap melalui saluran uap yang didukung oleh sejumlah perangkat pendukung. Salah satu perangkat penting penunjang sistem pembuangan adalah Inducted Draft Fan (ID FAN). ID Fan adalah sejenis kipas yang digunakan untuk menyedot sisa udara pembakaran (gas buang) dari dalam boiler menuju cerobong asap. ID Fan berfungsi untuk menjaga tekanan didalam boiler dan beroprasi pada tekanan atmosfer rendah sehingga tekanan nya negatif. Jika ID Fan tidak beroprasi normal atau dianggap rusak. Maka perpindahan gas buang ke cerobong tidak dapat terjadi dan akibatnya akan sangat serius bagi pengoprasian boiler dan produksi energi listrik. Dalam hal ini seluruh parameter data pengoprasian dibawah batas toleransi (sesuai standar),sehingga dapat dianggap bahwa ID Fan dan motornya dalam keadaan optimal.

The steam power plant UJP LONTAR PLN (persero) supplies 3x315MW produced from 3 pipe units. The PLTU has been operating for about is 945 MW. The power plant has a combustion disposal system that is used to transfer the exhaus gas residue in the boiler to the smoke tubes through steam channels suporrted by a number of suppoerting devices of the exhaust system is the induction fan. ID Fan is a type of fan that is used to suckthe residue of combution air (exhaust gas) from the boiler to the smoke hole. ID fan serves to keep the pressure inside a boiler and operate at low atmospheric pressure so that the pressure is negative.
If the Fan ID is not operating normally or is considered to be damaged. Then the transfer of exhaustive gas to the hole cannot occur and the consequences will be very serious for the operation of the boilers and the productions of electricity. In this case,the entire operating data parameters of the ID Fan and the motor are still working normally and still operating below the tolerance limits ( as standard), so it be considered that the ID and motor fan are in optimal condition.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Induced Draft Fan, Boiler and Fuel gas, Overhaul PLTU
Subjects: Bidang Keilmuan > Maintenance
Bidang Keilmuan > Mechanical Engineering
Skripsi
Bidang Keilmuan > Teknik Mesin
Divisions: Vokasi > D3 Teknologi Mesin
Depositing User: Yudha Formanto
Date Deposited: 10 Sep 2025 02:33
Last Modified: 10 Sep 2025 02:33
URI: https://repository.itpln.ac.id/id/eprint/769

Actions (login required)

View Item
View Item