Abstract
Indonesia merupakan negara dengan intensitas gempa bumi yang tinggi. Salah satunya kota di Indonesia yaitu Kebumen. Oleh karena itu, pembangunan infrastruktur di Indonesia harus mempertimbangkan beban akibat gempa dalam perancangannya. Untuk mengetahui perilaku struktur akibat beban gempa perlu dilakukan analisis dinamik. Dalam penelitian ini metode yang digunakan adalah time history. Struktur yang dianalisis dalam penelitian ini adalah Gedung Rumah Sakit PKU Muhammadiyah Gombong yang sesuai dengan gempa pada tahun 2017 di Cilacap yang berkekuatan 6,9 SR. Penelitian ini mengkaji kinerja struktur gedung yaitu base shear dan simpangan antar lantai. Respon spektrum yang digunakan adalah respon spektrum kota Kebumen berdasarkan SNI 1726-2012 sedangkan riwayat gempa yang digunakan dalam penelitian ini adalah riwayat gempa Landers, Taiwan, Trinidad, Kocaeli. Hasil kinerja batas layan arah X lantai helipad untuk kocaeli=0,7 x 10-7; Landers=0,94 x 10-3; Taiwan=2,050 x 10-3; dan Trained=4,720 x 10-3. Hasil kinerja batas layan arah Y lantai helipad untuk kocaeli=0,2 x 10-7; Landers=1 x 10-3; Taiwan=1,269 x 10-3; dan Trained=9,805 x 10-3. Dari hasil kinerja batas layan arah X maupun Y masih tergolong aman karena memenuhi syarat.
Indonesia is a country with high earthquake intensity. One of the cities in Indonesia is Kebumen. Therefore, infrastructure development in Indonesia must consider the burden caused by the earthquake in its design. To find out the behavior of the structure due to earthquake load it is necessary to do dynamic analysis. In this study the method used is time history. The structure analyzed in this study is PKU Muhammadiyah Gombong Hospital Building which is in accordance with the earthquake in 2017 in Cilacap with a magnitude of 6.9 SR. This study examines the performance of building structures namely base shears and intersections between floors. The spectrum response used is the response spectrum of the city of Kebumen based on SNI-1726-2012 while the earthquake history used in this study is a history of earthquake Landers, Taiwan, Trinidad, Kocaeli. The result direction X for helipad kocaeli=0,7 x 10-7; Landers=0,94 x 10-3; Taiwan=2,050 x 10-3; dan Trained=4,720 x 10-3. The result direction Y for helipad kocaeli=0,2 x 10-7; Landers=1 x 10-3; Taiwan=1,269 x 10-3; dan Trained=9,805 x 10-3. The result direction X and Y of performance serve load are still safe because in qualify.
Item Type: | Thesis (Diploma) |
---|---|
Uncontrolled Keywords: | gempa bumi, time history, gaya geser dasar, simpangan earthquake, time history, base shear force, displacement |
Subjects: | Bidang Keilmuan > Teknik Sipil Skripsi |
Divisions: | Fakultas Teknologi Infrastruktur dan Kewilayahan > S1 Teknik SIpil |
Depositing User: | Sudarman |
Date Deposited: | 10 Sep 2025 03:33 |
Last Modified: | 10 Sep 2025 03:33 |
URI: | https://repository.itpln.ac.id/id/eprint/786 |