PENGARUH OVERHAUL TERHADAP EFEKTIVITAS KONDENSOR PLTU BANTEN 1×660 MW PT. LESTARI BANTEN ENERGI

SAPUTRA, RANDI and Sulistiyo, Eko and Sulistiyo, Eko (2024) PENGARUH OVERHAUL TERHADAP EFEKTIVITAS KONDENSOR PLTU BANTEN 1×660 MW PT. LESTARI BANTEN ENERGI. Diploma thesis, ITPLN.

[thumbnail of TUGAS AKHIR_RANDI SAPUTRA_202172011.pdf] Text
TUGAS AKHIR_RANDI SAPUTRA_202172011.pdf
Restricted to Repository staff only

Download (8MB)

Abstract

PT. Lestari Banten Energi adalah salah satu PLTU swasta di Indonesia dengan kapasitas 1 × 660 MW. PT. Lestari Banten Energi terletak di Kecamatan Puloampel, Kabupaten Serang. Untuk mengondensasikan uap yang keluar dari turbin bertenaga uap PT. Lestari Banten Energi menggunakan kondensor bertipe permukaan atau surface condenser. Air pendingin dari air laut digunakan oleh PLTU Banten. Air ini langsung masuk ke Circulating Water Pump (CWP), lalu dialirkan ke Debris Filter untuk difilter, dan kemudian langsung menuju kondensor. Perawatan atau overhaul kondensor harus dilakukan secara berkala untuk memastikan bahwa efektivitas dan performa tetap optimal. Nilai perpindahan panas pada kondensor terjadi perubahan setelah dilakukannya overhaul yang semula 30,107°C setelah dilakukannya overhaul nilainya menjadi 29,409°C, hal serupa terjadi pada laju perpindahan panas kondensor yang terjadi perubahan di mana sebelum overhaul nilainya 189485,84498 kJ/s dan setelah dilakukan overhaul menjadi 189467,72992 kJ/s. Perbedaan selisih efektivitas sebelum dan sesudah overhaul pada kondensor PLTU PT. Lestari Banten Energi sebesar 2,895 %, karena efektivitas kondensor sebelum overhaul adalah 0,3958 % dan efektivitas setelah overhaul meningkat menjadi 0,4076 %.

PT. Lestari Banten Energi is one of the private PLTUs in Indonesia with a capacity of 1 × 660 MW. PT. Lestari Banten Energi is located in Puloampel District, Serang Regency. To condense the steam coming out of PT's steam powered turbine. Lestari Banten Energi uses a surface type condenser. Cooling water from sea water is used by PLTU Banten. This water goes directly to the Circulating Water Pump (CWP), then flows to the Debris Filter to be filtered, and then goes straight to the condenser. Condenser maintenance or overhaul must be carried out regularly to ensure that effectiveness and performance remain optimal. The heat transfer value in the condenser changed after the overhaul which was originally 30.107°C after the overhaul the value became 29.409°C, the same thing happened to the condenser heat transfer rate which changed where before the overhaul the value was 189485.84498 kJ/s and after the overhaul to 189467.72992 kJ/s. The difference in effectiveness before and after overhaul of the PLTU PT condenser. Lestari Banten Energi was 2.895%, because the effectivness of the condenser before the overhaul was 0.3958% and the effectivness after the overhaul increased to 0.4076%.

Item Type: Thesis (Diploma)
Uncontrolled Keywords: Kondensor, Overhaul, Efektivitas Kondensor, Heat Transfer, PLTU
Subjects: Bidang Keilmuan > Heat Transfer
Bidang Keilmuan > Maintenance
Bidang Keilmuan > Power generation
Bidang Keilmuan > Pump
Skripsi
Bidang Keilmuan > Teknik Mesin